Home LiteratureArticle Details
PMID: 10954285 Published · ppublish English Journal Article

Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms.

AJNR. American journal of neuroradiology ·Vol. 21 ·No. 7 ·2000-08-00 ·Pages 1312-4

Cloft HJ, Joseph GJ, Tong FC, Goldstein JH, Dion JE

Abstract

A three-dimensional Guglielmi detachable coil (3D-GDC) has been developed that is designed specifically to bridge the neck of an aneurysm with coil loops, thereby facilitating retention of additional coils placed within the aneurysm. Nine wide-necked cerebral aneurysms were successfully embolized using the 3D-GDC, provided that the dome-to-neck ratio was 1.5 or greater.

MeSH Terms
Aged Aged, 80 and over Cerebral Angiography Embolization, Therapeutic/instrumentation Equipment Design Female Humans Intracranial Aneurysm/diagnostic imaging,therapy Male Middle Aged
Authors & Affiliations
5 authors, click to expand affiliations / ORCID
Cloft H J
Department of Radiology, Emory University Hospital, Atlanta, GA 30322, USA.
Joseph G J
Tong F C
Goldstein J H
Dion J E
References (6)
6 references, click to expand
  1. Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.
    AJNR Am J Neuroradiol. 1994 May;15(5):815-20 PMID: 8059647
  2. Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization.
    AJNR Am J Neuroradiol. 1999 Mar;20(3):391-9 PMID: 10219403
  3. The "Remodelling Technique" in the Treatment of Wide Neck Intracranial Aneurysms. Angiographic Results and Clinical Follow-up in 56 Cases.
    Interv Neuroradiol. 1997 Mar 30;3(1):21-35 PMID: 20678369
  4. Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature.
    J Neurosurg. 1997 Dec;87(6):944-9 PMID: 9384409
  5. Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary University of Illinois at Chicago experience.
    Neurosurgery. 1998 Dec;43(6):1281-95; discussion 1296-7 PMID: 9848841
  6. Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms.
    AJNR Am J Neuroradiol. 1998 Jun-Jul;19(6):1176-8 PMID: 9672035
Article Info
Journal
AJNR. American journal of neuroradiology
Abbr.
AJNR Am J Neuroradiol
ISSN
0195-6108
Published
2000-08-00
Pages
1312-4
Language
English
Region
United States
NLM ID
8003708
PMCID
PMC8174921
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]