Home LiteratureArticle Details
PMID: 11277213 Published · ppublish English Comparative Study Journal Article Research Support, Non-U.S. Gov't

Rapid SPECT simulation of downscatter in non-uniform media.

Physics in medicine and biology ·Vol. 46 ·No. 3 ·2001-03-00 ·页码 621-35

de Jong HW, Beekman FJ

Abstract

A rotation-based Monte Carlo (MC) simulation method (RMC) has been developed, designed for rapid calculation of downscatter through non-uniform media in SPECT. A possible application is downscatter correction in dual isotope SPECT. With RMC, only a fraction of all projections of a SPECT study have to be MC simulated in a standard manner. The other projections can be estimated rapidly using the results of these standard MC calculations. For efficiency, approximations have to be made in RMC with regard to the final scatter angle of the detected photons. Further speed-up is obtained by combining RMC with convolution-based forced detection (CFD) instead of forced detection (FD), which is a more common variance reduction technique for MC. The RMC method was compared with standard MC for 99mTc downscatter in a 201Tl window (72 keV+/-10%) using a digital thorax phantom. The resulting scatter projections are in good agreement (maximum bias a few per cent of the largest value in the projection), but RMC with CFD is about three orders in magnitude faster than standard MC with FD and up to 25 times faster than standard MC with CFD. Using RMC combined with CFD, the generation of 64 almost noise-free downscatter projections (64 x 64) takes only a couple of minutes on a 500 MHz Pentium processor. Therefore, rotation-based Monte Carlo could serve as a practical tool for downscatter correction schemes in dual isotope SPECT.

MeSH 主题词
Humans Image Processing, Computer-Assisted Monte Carlo Method Phantoms, Imaging Radiography, Thoracic Reproducibility of Results Scattering, Radiation Technetium Thallium Radioisotopes Tomography, Emission-Computed, Single-Photon
化学物质
Thallium Radioisotopes Technetium
作者与单位
共 2 位作者,点击展开单位 / ORCID
de Jong H W
Department of Nuclear Medicine, Image Sciences Institute, University Medical Center, Utrecht, The Netherlands.
Beekman F J
Article Info
Journal
Physics in medicine and biology
Abbr.
Phys Med Biol
ISSN
0031-9155
Published
2001-03-00
页码
621-35
Language
English
Country/Region
England
NLM ID
0401220
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]