Home LiteratureArticle Details
PMID: 12096265 Published · ppublish English Clinical Trial Clinical Trial, Phase II Clinical Trial, Phase III Comparative Study Journal Article Review

The use of color-flow duplex scan for the detection of endoleaks.

Journal of vascular surgery ·Vol. 36 ·No. 1 ·2002-07-00 ·页码 100-4

McLafferty RB, McCrary BS, Mattos MA, Karch LA, Ramsey DE, Solis MM, Hodgson KJ

Abstract

Computed tomographic (CT) scan represents the criterion standard for surveillance of endoleaks after endoluminal repair of abdominal aortic aneurysms (erAAAs). Given need for surveillance, risks, and expense of CT scan, the accuracy of color-flow duplex (CFD) scan after erAAA was determined. During a 43-month period, patients enrolled in phase II and III of the AneuRx Multicenter Clinical Trial at our institution underwent CFD scan 1 month after erAAA. Patients with CFD scan results that were positive for endoleak underwent CT scanning at 3 months after erAAA, and those with CFD scan results that were negative for endoleak underwent CT scanning at 6 months after erAAA. Seven of 79 patients (9%) who underwent CFD and CT scanning had the diagnosis of endoleak. All endoleaks that were diagnosed with CT scan were detected with CFD scan. One patient had positive results for endoleak with CFD scan at 1 month and then negative results with CT scan at 3 months. Although this may represent resolution of endoleak, this case was counted as a false-positive result. When compared with CT scan, CFD scan had a sensitivity of 100%, specificity of 99%, positive predictive value of 88%, negative predictive value of 100%, and accuracy of 99%. CFD scan is an accurate test for the detection of endoleak after erAAA. In addition, most endoleaks diagnosed with CFD scan at 1 month continued to be present at 6 months. This important finding increases the emphasis on the use of this noninvasive test and may initiate earlier intervention of endoleak.

MeSH 主题词
Aortic Aneurysm, Abdominal/diagnosis False Positive Reactions Follow-Up Studies Humans Predictive Value of Tests Sensitivity and Specificity Tomography, X-Ray Computed Ultrasonography, Doppler, Duplex/statistics & numerical data
作者与单位
共 7 位作者,点击展开单位 / ORCID
McLafferty Robert B
Division of Vascular Surgery, Department of Surgery, Southern Illinois University, School of Medicine, Springfield, 62794-9638, USA. [email protected]
McCrary Bradford S
Mattos Mark A
Karch Laura A
Ramsey Don E
Solis Maurice M
Hodgson Kim J
Article Info
Journal
Journal of vascular surgery
Abbr.
J Vasc Surg
ISSN
0741-5214
Corresponding email
Published
2002-07-00
页码
100-4
Language
English
Country/Region
United States
NLM ID
8407742
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]