Home LiteratureArticle Details
PMID: 12406864 Published · ppublish English Journal Article Research Support, U.S. Gov't, P.H.S. Validation Study

An investigation of air inlet velocity in simulating the dispersion of indoor contaminants via computational fluid dynamics.

The Annals of occupational hygiene ·Vol. 46 ·No. 8 ·2002-11-00 ·页码 701-12

Lee E, Feigley CE, Khan J

Abstract

Computational fluid dynamics (CFD) is potentially a valuable tool for simulating the dispersion of air contaminants in workrooms. However, CFD-estimated airflow and contaminant concentration patterns have not always shown good agreement with experimental results. Thus, understanding the factors affecting the accuracy of such simulations is critical for their successful application in occupational hygiene. The purposes of this study were to validate CFD approaches for simulating the dispersion of gases and vapors in an enclosed space at two air flow rates and to demonstrate the impact of one important determinant of simulation accuracy. The concentration of a tracer gas, isobutylene, was measured at 117 points in a rectangular chamber [1 (L) x 0.3 (H) x 0.7 m (W)] using a photoionization analyzer. Chamber air flow rates were scaled using geometric and kinematic similarity criteria to represent a full-sized room at two Reynolds numbers (Re = 5 x 10(2) and 5 x 10(3)). Also, CFD simulations were conducted to estimate tracer gas concentrations throughout the chamber. The simulation results for two treatments of air inlet velocity (profiled inlet velocity measured in traverses across the air inlet and the assumption that air velocity is uniform across the inlet) were compared with experimental observations. The CFD-simulated 3-dimensional distribution of tracer gas concentration using the profiled inlet velocity showed better agreement qualitatively and quantitatively with measured chamber concentration, while the concentration estimated using the uniform inlet velocity showed poor agreement for both comparisons. For estimating room air contaminant concentrations when inlet velocities can be determined, this study suggests that using the inlet velocity distribution to define inlet boundary conditions for CFD simulations can provide more reliable estimates. When the inlet velocity distribution is not known, for instance for prospective design of dilution ventilation systems, the trials of several velocity profiles with different source, air inlet and air outlet locations may be useful for determining the most efficient workroom layout.

MeSH 主题词
Air Movements Air Pollution, Indoor/analysis Computer Simulation/standards Humans Models, Theoretical Occupational Exposure Workplace
作者与单位
共 3 位作者,点击展开单位 / ORCID
Lee Eungyoung
Department of Environmental Health Sciences, HESC, Room 311, Norman J Arnold School of Public Health, University of South Carolina, Columbia 29208, USA. [email protected]
Feigley Charles E
Khan Jamil
Article Info
Journal
The Annals of occupational hygiene
Abbr.
Ann Occup Hyg
ISSN
0003-4878
Corresponding email
Published
2002-11-00
页码
701-12
Language
English
Country/Region
England
NLM ID
0203526
基金资助
NIOSH CDC HHS · OH07626 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]