Abstract
Real-time PCR is being used increasingly as the method of choice for mRNA quantification, allowing rapid analysis of gene expression from low quantities of starting template. Despite a wide range of approaches, the same principles underlie all data analysis, with standard approaches broadly classified as either absolute or relative. In this study we use a variety of absolute and relative approaches of data analysis to investigate nocturnal c-fos expression in wild-type and retinally degenerate mice. In addition, we apply a simple algorithm to calculate the amplification efficiency of every sample from its amplification profile. We confirm that nocturnal c-fos expression in the rodent eye originates from the photoreceptor layer, with around a 5-fold reduction in nocturnal c-fos expression in mice lacking rods and cones. Furthermore, we illustrate that differences in the results obtained from absolute and relative approaches are underpinned by differences in the calculated PCR efficiency. By calculating the amplification efficiency from the samples under analysis, comparable results may be obtained without the need for standard curves. We have automated this method to provide a means of streamlining the real-time PCR process, enabling analysis of experimental samples based upon their own reaction kinetics rather than those of artificial standards.
MeSH Terms
Actins/genetics
Animals
DNA, Complementary/genetics,metabolism
Gene Expression
Mice
Mice, Mutant Strains
Polymerase Chain Reaction/methods,standards
Proto-Oncogene Proteins c-fos/genetics
RNA, Messenger/genetics,metabolism
Reference Standards
Reproducibility of Results
Chemicals
Actins
DNA, Complementary
Proto-Oncogene Proteins c-fos
RNA, Messenger
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Peirson Stuart N
Department of Integrative and Molecular Neuroscience, Division of Neuroscience and Psychological Medicine, Faculty of Medicine, Imperial College London, Charing Cross Hospital, Fulham Palace Road, London W6 8RF, UK.
Butler Jason N
Foster Russell G
References (18)
18 references, click to expand
-
Control selection for RNA quantitation.
Biotechniques. 2000 Aug;29(2):332-7
PMID: 10948434
-
Regulation of the mammalian pineal by non-rod, non-cone, ocular photoreceptors.
Science. 1999 Apr 16;284(5413):505-7
PMID: 10205062
-
Quantitative reverse transcription-polymerase chain reaction to study mRNA decay: comparison of endpoint and real-time methods.
Anal Biochem. 2000 Oct 15;285(2):194-204
PMID: 11017702
-
The PCR plateau phase - towards an understanding of its limitations.
Biochim Biophys Acta. 2000 Nov 15;1494(1-2):23-7
PMID: 11072065
-
Control genes in quantitative molecular biological techniques: the variability of invariance.
Comp Biochem Physiol B Biochem Mol Biol. 2001 Oct;130(3):281-9
PMID: 11567890
-
A new quantitative method of real time reverse transcription polymerase chain reaction assay based on simulation of polymerase chain reaction kinetics.
Anal Biochem. 2002 Mar 1;302(1):52-9
PMID: 11846375
-
Analysis of relative gene expression data using real-time quantitative PCR and the 2(-Delta Delta C(T)) Method.
Methods. 2001 Dec;25(4):402-8
PMID: 11846609
-
Validation of a quantitative method for real time PCR kinetics.
Biochem Biophys Res Commun. 2002 Jun 7;294(2):347-53
PMID: 12051718
-
Gene quantification using real-time quantitative PCR: an emerging technology hits the mainstream.
Exp Hematol. 2002 Jun;30(6):503-12
PMID: 12063017
-
Quantification using real-time PCR technology: applications and limitations.
Trends Mol Med. 2002 Jun;8(6):257-60
PMID: 12067606
-
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems.
J Mol Endocrinol. 2002 Aug;29(1):23-39
PMID: 12200227
-
A new mathematical model for relative quantification in real-time RT-PCR.
Nucleic Acids Res. 2001 May 1;29(9):e45
PMID: 11328886
-
Differential expression of c-fos mRNA in rat retinal cells: regulation by light/dark cycle.
Neuron. 1993 Jun;10(6):1049-54
PMID: 8318229
-
Diurnal expression of c-fos in the mouse retina.
Brain Res Mol Brain Res. 1993 Jul;19(1-2):47-54
PMID: 7689683
-
Kinetic PCR analysis: real-time monitoring of DNA amplification reactions.
Biotechnology (N Y). 1993 Sep;11(9):1026-30
PMID: 7764001
-
Quantitative RT-PCR: pitfalls and potential.
Biotechniques. 1999 Jan;26(1):112-22, 124-5
PMID: 9894600
-
Regulation of mammalian circadian behavior by non-rod, non-cone, ocular photoreceptors.
Science. 1999 Apr 16;284(5413):502-4
PMID: 10205061
-
Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays.
J Mol Endocrinol. 2000 Oct;25(2):169-93
PMID: 11013345