Abstract
Capillary HPLC is a very effective means of separating small amounts of peptides and proteins. Capillary columns ranging from 0.01 mm to 0.5 mm in diameter can be constructed using recycled supports and inexpensive fused silica capillary tubing. Commercial pumping systems and UV detectors can be readily converted for operation in the flow rate range of 0.5-50 microL/min. Detailed procedures are given for the construction of columns and UV detector flow cells. A mixture of peptides derived from the endo Lys C digest of horse heart cytochrome c was used to illustrate various aspects of capillary chromatography of peptides and compares the performance of various-sized capillary columns and UV detector flow cell types.
MeSH Terms
Amino Acid Sequence
Animals
Chromatography, High Pressure Liquid/instrumentation,methods
Cytochrome c Group/chemistry
Horses
Mass Spectrometry
Molecular Sequence Data
Oligopeptides/analysis,chemistry,isolation & purification
Peptide Fragments/analysis,chemistry,isolation & purification
Peptides/analysis,chemistry,isolation & purification
Proteins/analysis,isolation & purification
Spectrophotometry, Ultraviolet
Chemicals
Cytochrome c Group
Oligopeptides
Peptide Fragments
Peptides
Proteins
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Davis M T
Division of Immunology, Beckman Research Institute of the City of Hope, Duarte, California 91010.
Lee T D
References (7)
7 references, click to expand
-
Optimization of the fragmentation in a frit-fast atom bombardment ion source for the sequencing of peptides at the picomole level.
Anal Chem. 1991 Sep 15;63(18):1978-83
PMID: 1750699
-
Enzymatic and chemical digestion of proteins for mass spectrometry.
Methods Enzymol. 1990;193:361-74
PMID: 1963671
-
Interfacing microbore and capillary liquid chromatography to continuous-flow fast atom bombardment mass spectrometry for the analysis of glycopeptides.
J Chromatogr. 1990 Aug 3;529(2):265-75
PMID: 2146280
-
Recent advances in microcolumn liquid chromatography.
Anal Chem. 1988 Apr 15;60(8):500A-510A
PMID: 3369701
-
Sampling and extra-column effects in high-performance liquid chromatography; influence of peak skew on plate count calculations.
J Chromatogr Sci. 1977 Aug;15(8):303-16
PMID: 893648
-
Analysis of proteins and glycoproteins at the picomole level by on-line coupling of microbore high-performance liquid chromatography with flow fast atom bombardment and electrospray mass spectrometry: a comparative evaluation.
Biomed Environ Mass Spectrom. 1990 Nov;19(11):677-91
PMID: 2076466
-
High-sensitivity peptide mapping by capillary zone electrophoresis and microcolumn liquid chromatography, using immobilized trypsin for protein digestion.
Anal Chem. 1989 Oct 15;61(20):2226-31
PMID: 2596696