Abstract
To assess the diagnostic accuracy of several measured and calculated indexes for early prediction of weaning outcome, and to study the value of supplemental inspiratory load in improving the accurate prediction of successful weaning. Prospective study. ICU of a University Hospital. Thirty consecutive patients under prolonged mechanical ventilation and without chronic obstructive pulmonary disease (COPD). Forty weaning trials were performed. Data were recorded at 15, 30 (adding inspiratory flow resistance), 60 and 120 min. The threshold values and the accuracy of three indexes were determined: Inspiratory airway occlusion pressure at 0.1 sec. (P01) to maximum inspiratory pressure ratio (P01/MIP), inspiratory effort quotient (IEQ), and the ratio of respiratory frequency to tidal volume (F/Vt). All three were useful predictors for weaning success with a diagnostic accuracy between 82%-87%. At 15 min of spontaneous breathing, a P01/MIP ratio < 0.14 predicts weaning success with a sensitivity of 82% and specificity of 83%. In our group of patients no reintubation was necessary. The application of mechanical inspiratory load significantly increased P01 values (3.16 +/- 1.22 to 3.60 +/- 1.19, p < 0.001). The degree of the P01 increase did not provide prediction of weaning outcome. a) P01/MIP, IEQ and F/Vt ratio were accurate, early predictors of weaning outcome. b) The addition of a moderate mechanical inspiratory load did not enhance the diagnostic accuracy of P01 measurements. c) In our patients, a period of two hours seemed to be sufficient for development and detection of weaning failure.
MeSH Terms
Adult
Aged
Airway Resistance
Female
Hospitals, University
Humans
Inspiratory Capacity
Intensive Care Units
Male
Middle Aged
Predictive Value of Tests
Prospective Studies
Respiration
Severity of Illness Index
Spain
Tidal Volume
Treatment Outcome
Ventilator Weaning/methods,standards,statistics & numerical data
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Gandia F
Servicio de Medicina Intensiva, Hospital Clinico Universitario, Valladolid, Spain.
Blanco J
References (25)
25 references, click to expand
-
Force-length relationship of the normal human diaphragm.
J Appl Physiol Respir Environ Exerc Physiol. 1982 Aug;53(2):405-12
PMID: 7118662
-
Comparison of standard weaning parameters and the mechanical work of breathing in mechanically ventilated patients.
Chest. 1988 Aug;94(2):232-8
PMID: 3396396
-
The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation.
Am Rev Respir Dis. 1986 Dec;134(6):1111-8
PMID: 3789513
-
Selection and interpretation of diagnostic tests and procedures. Principles and applications.
Ann Intern Med. 1981 Apr;94(4 Pt 2):557-92
PMID: 6452080
-
Extubation criteria.
Crit Care Med. 1986 Feb;14(2):169
PMID: 3943325
-
Hyperinflation.
Am Rev Respir Dis. 1984 Jan;129(1):1-2
PMID: 6703469
-
Work of breathing: reliable predictor of weaning and extubation.
Crit Care Med. 1990 Feb;18(2):157-62
PMID: 2298006
-
P 0.1/PIMax: an index for assessing respiratory capacity in acute respiratory failure.
Intensive Care Med. 1990;16(3):175-9
PMID: 2191019
-
Criteria for weaning from prolonged mechanical ventilation.
Arch Intern Med. 1984 May;144(5):1012-6
PMID: 6712394
-
Weaning from mechanical ventilation.
N Engl J Med. 1991 May 23;324(21):1496-8
PMID: 2023609
-
Weaning patients from mechanical ventilation.
Intensive Care Med. 1984;10(2):55-8
PMID: 6371092
-
Is weaning an art or a science?
Am Rev Respir Dis. 1986 Dec;134(6):1107-8
PMID: 3789511
-
Predicting weaning outcome.
Chest. 1988 Aug;94(2):227-8
PMID: 3396393
-
Clinical manifestations of inspiratory muscle fatigue.
Am J Med. 1982 Sep;73(3):308-16
PMID: 6812417
-
Extubation criteria after weaning from intermittent mandatory ventilation and continuous positive airway pressure.
Crit Care Med. 1983 Sep;11(9):702-7
PMID: 6411431
-
Mouth occlusion pressure (P0.1) in acute respiratory failure.
Intensive Care Med. 1985;11(3):134-9
PMID: 3998273
-
Evaluation of two different extubation criteria: attributes contributing to success.
Crit Care Med. 1986 Feb;14(2):92-4
PMID: 3510814
-
A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation.
N Engl J Med. 1991 May 23;324(21):1445-50
PMID: 2023603
-
Prediction of successful ventilator weaning using airway occlusion pressure and hypercapnic challenge.
Chest. 1987 Apr;91(4):496-9
PMID: 3829740
-
New tests to assess lung function: occlusion pressure--a simple measure of the respiratory center's output.
N Engl J Med. 1975 Nov 13;293(20):1029-30
PMID: 1101064
-
Tracheal occlusion pressure: a simple index to monitor respiratory muscle fatigue during acute respiratory failure in patients with chronic obstructive pulmonary disease.
Ann Intern Med. 1988 Jun;108(6):800-5
PMID: 3369770
-
Weaning from mechanical ventilation.
Am Rev Respir Dis. 1988 Oct;138(4):1043-6
PMID: 3202430
-
Weaning from mechanical ventilation.
JAMA. 1976 May 17;235(20):2208-12
PMID: 946845
-
Occlusion pressure as a measure of respiratory center output in conscious man.
Respir Physiol. 1975 Mar;23(2):181-99
PMID: 1144940
-
Airway occlusion pressure. An important indicator for successful weaning in patients with chronic obstructive pulmonary disease.
Am Rev Respir Dis. 1987 Jan;135(1):107-13
PMID: 3800139