PMID: 15052387 Published · ppublish English Journal Article

Diagnosis of ventilator-associated pneumonia: agreement between quantitative cultures of endotracheal aspiration and plugged telescoping catheter.

Intensive care medicine ·Vol. 30 ·No. 5 ·2004-05-00 ·Pages 853-8

Elatrous S, Boukef R, Ouanes Besbes L, Marghli S, Nooman S, Nouira S, Abroug F

Abstract

To evaluate the diagnostic agreement between quantitative cultures of samples obtained with endotracheal aspiration (ETA) and plugged telescoping catheter (PTC). Prospective study. Medical ICU. Hundred thirty-eight episodes of suspected ventilator-associated pneumonia studied in 100 consecutive patients. For each suspected episode of ventilator-associated pneumonia, ETA and PTC were performed consecutively. The agreement between microbiological results obtained from the two techniques was evaluated (kappa statistic test). Pneumonia was diagnosed on a positive culture result of telescoping catheter with the threshold set at 10(3) cfu/ml or more. The cut-off points evaluated for ETA ranged from 10(2 )to 10(6) cfu/ml. Micro-organisms retrieved by aspiration and telescoping catheter were similar and bacterial counts obtained by the two procedures were well correlated ( r = 0.71 p < 0.001). There was good agreement between positive and negative ETA and PTC specimens (kappa: 0.78) with a diagnostic threshold for ETA of 10(4) cfu/ml. The sensitivity and specificity of ETA for the diagnosis of PTC-confirmed pneumonia were 92% and 85%, respectively. Kappa decreased to 0.48 when the diagnostic threshold was increased to 10(6) cfu/ml. Quantitative cultures of ETA and PTC tallied for both micro-organisms and counts. The simpler ETA appears adequate for determining the presence of pathogenic organisms in significant concentration in the lower respiratory tract.

MeSH Terms
Bacteria/classification,isolation & purification Catheterization/instrumentation Female Humans Male Middle Aged Pneumonia, Bacterial/diagnosis,etiology,mortality Prospective Studies ROC Curve Reproducibility of Results Respiration, Artificial/adverse effects Specimen Handling/instrumentation,methods
Authors & Affiliations
7 authors, click to expand affiliations / ORCID
Elatrous Souheil
Intensive Care Unit, Centre Hospitalo-Universitaire F. Bourguiba, 5000 Monastir, Tunisia.
Boukef Riadh
Ouanes Besbes Lamia
Marghli Soudani
Nooman Sami
Nouira Semir
Abroug Fekri
References (23)
23 references, click to expand
  1. Diagnostic value of quantitative cultures of bronchoalveolar lavage and telescoping plugged catheters in mechanically ventilated patients with bacterial pneumonia.
    Am Rev Respir Dis. 1989 Aug;140(2):306-10 PMID: 2764366
  2. Ventilator-associated pneumonia.
    Am J Respir Crit Care Med. 2002 Apr 1;165(7):867-903 PMID: 11934711
  3. Comparison of tracheal aspirates and protected brush catheter specimens for identifying pathogenic bacteria in mechanically ventilated patients.
    Am J Med Sci. 1989 Jun;297(6):377-82 PMID: 2472060
  4. Specificity of endotracheal aspiration, protected specimen brush, and bronchoalveolar lavage in mechanically ventilated patients.
    Am Rev Respir Dis. 1993 Apr;147(4):952-7 PMID: 8466132
  5. Diagnostic efficiency of endotracheal aspirates with quantitative bacterial cultures in intubated patients with suspected pneumonia. Comparison with the protected specimen brush.
    Am Rev Respir Dis. 1993 Jul;148(1):138-44 PMID: 8317789
  6. Cardiopulmonary effects of bronchoalveolar lavage in critically ill patients.
    Chest. 1993 Nov;104(5):1541-7 PMID: 8222821
  7. Histopathologic and microbiologic aspects of ventilator-associated pneumonia.
    Anesthesiology. 1996 Apr;84(4):760-71 PMID: 8638829
  8. Etiologic diagnosis of bacterial nosocomial pneumonia in seriously ill patients.
    Crit Care Med. 1985 Oct;13(10):833-6 PMID: 4028753
  9. Diagnosis of nosocomial pneumonia in mechanically ventilated patients by the blind protected telescoping catheter.
    Intensive Care Med. 1993;19(7):377-82 PMID: 8270716
  10. Pulmonary pathology in acute respiratory insufficiency: lung biopsy as a diagnostic tool.
    J Thorac Cardiovasc Surg. 1976 Jan;71(1):64-71 PMID: 765628
  11. Diagnostic tests for pneumonia in ventilated patients: prospective evaluation of diagnostic accuracy using histology as a diagnostic gold standard.
    Am J Respir Crit Care Med. 1995 Jun;151(6):1878-88 PMID: 7767535
  12. Role of quantitative cultures of endotracheal aspirates in the diagnosis of nosocomial pneumonia.
    Am J Respir Crit Care Med. 1995 Jul;152(1):241-6 PMID: 7599831
  13. Fiberoptic bronchoscopy in ventilated patients. Evaluation of cardiopulmonary risk under midazolam sedation.
    Chest. 1990 Apr;97(4):927-33 PMID: 2108848
  14. Effect of previous antimicrobial therapy on the accuracy of the main procedures used to diagnose nosocomial pneumonia in patients who are using ventilation.
    Chest. 1995 Oct;108(4):1036-40 PMID: 7555116
  15. Diagnosis of nosocomial pneumonia in mechanically ventilated patients. Comparison of a plugged telescoping catheter with the protected specimen brush.
    Am Rev Respir Dis. 1991 May;143(5 Pt 1):1055-61 PMID: 2024814
  16. Invasive and noninvasive strategies for management of suspected ventilator-associated pneumonia. A randomized trial.
    Ann Intern Med. 2000 Apr 18;132(8):621-30 PMID: 10766680
  17. A new Simplified Acute Physiology Score (SAPS II) based on a European/North American multicenter study.
    JAMA. 1993 Dec 22-29;270(24):2957-63 PMID: 8254858
  18. The measurement of observer agreement for categorical data.
    Biometrics. 1977 Mar;33(1):159-74 PMID: 843571
  19. Bacteriologic diagnosis of nosocomial pneumonia in primates. Usefulness of the protected specimen brush.
    Am Rev Respir Dis. 1982 Jan;125(1):53-7 PMID: 7065510
  20. Quantitative cultures of endotracheal aspirates for the diagnosis of ventilator-associated pneumonia.
    Am Rev Respir Dis. 1993 Dec;148(6 Pt 1):1552-7 PMID: 8256899
  21. Diagnosis of nosocomial pneumonia in intubated, intensive care unit patients.
    Am Rev Respir Dis. 1987 Feb;135(2):426-32 PMID: 3101559
  22. [Diagnosis of ventilator-associated pneumonia: a prospective comparison of the telescoping plugged catheter with the endotracheal aspirate].
    Ann Fr Anesth Reanim. 2002 Mar;21(3):184-92 PMID: 11963381
  23. Bacteriologic diagnosis of nosocomial pneumonia following prolonged mechanical ventilation.
    Am Rev Respir Dis. 1988 Feb;137(2):259-64 PMID: 3341619
Article Info
Journal
Intensive care medicine
Abbr.
Intensive Care Med
ISSN
0342-4642
Published
2004-05-00
Epub
2004-00-30
Pages
853-8
Language
English
Region
United States
NLM ID
7704851
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]