Home LiteratureArticle Details
PMID: 15282812 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.

Factors affecting the accuracy of pressure measurements in vascular stenoses from phase-contrast MRI.

Magnetic resonance in medicine ·Vol. 52 ·No. 2 ·2004-08-00 ·页码 300-9

Nasiraei-Moghaddam A, Behrens G, Fatouraee N, Agarwal R, Choi ET, Amini AA

Abstract

In this work the effects of noise, resolution, and velocity (flow) on the measurement of intravascular pressure from phase-contrast (PC) MRI are discussed. To elucidate these effects, we employed an axisymmetric geometry that enabled us to calculate pressures in <2 min on a Sun Ultra SPARC 10 workstation. To determine the effects of vascular stenoses, we fabricated several stenotic phantom geometries (with 50%, 75%, and 90% area stenoses), and performed both MRI and computational fluid dynamics (CFD) simulations for various flow rates for these phantom geometries. Noise with Gaussian statistics was added to the velocity field obtained from the CFD simulations. The pressure maps obtained directly from CFD simulations for our phantom geometries were compared with pressure maps derived by our algorithm when 1) the input was noise-corrupted velocity data from CFD, and 2) the input was PC-MRI data collected from the phantoms. The quantitative effects of noise, resolution, and flow rate on the accuracy of pressure measurements were determined. We found that for flow rates below the Reynolds number for turbulent flow, resolution is a more significant determinant of accuracy than SNR. Furthermore, if other parameters remain constant, increased flow rates may result in decreased accuracy.

MeSH 主题词
Algorithms Blood Flow Velocity Blood Pressure/physiology Constriction, Pathologic/physiopathology Hemorheology Magnetic Resonance Imaging/methods Models, Cardiovascular Phantoms, Imaging Poisson Distribution Viscosity
作者与单位
共 6 位作者,点击展开单位 / ORCID
Nasiraei-Moghaddam Abbas
CVIA Laboratory, Washington University School of Medicine, St. Louis, Missouri 63110, USA.
Behrens Geoffrey
Fatouraee Nasser
Agarwal Ramesh
Choi Eric T
Amini Amir A
Article Info
Journal
Magnetic resonance in medicine
Abbr.
Magn Reson Med
ISSN
0740-3194
Published
2004-08-00
页码
300-9
Language
English
Country/Region
United States
NLM ID
8505245
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]