Evaluation of a new automated electrochemiluminescent sex hormone-binding globulin (SHBG) immunoassay.

Clinical chemistry and laboratory medicine ·Vol. 43 ·No. 1 ·2005-00-00 ·Pages 86-9

Reynders M, Anckaert E, Schiettecatte J, Smitz J

Abstract

Serum sex hormone-binding globulin (SHBG) regulates the cellular bioavailability of SHBG-bound steroid hormones. Since variations in SHBG levels may affect the concentration of free, i.e., biologically active testosterone in serum, SHBG levels are commonly measured as a supplement to total testosterone determination. The recently developed electrochemiluminescence Elecsys SHBG immunoassay was evaluated analytically on a Modular E170 (Roche Diagnostics, Mannheim, Germany) immunoanalyzer. Major differences in SHBG concentrations have been described among the commercially available methods; we therefore compared the new method with an established SHBG immunoradiometric assay (IRMA) in 99 routine serum samples. To provide reference values to clinicians, SHBG concentration was measured by Elecsys in 304 serum samples from healthy volunteers and several relevant clinical subgroups. The within-run and total imprecision coefficients of variation were </=2.9% and </=3.3%, respectively. Functional sensitivity was at least 0.74 nmol/L. Recoveries after dilution of high-concentration samples in low-titer human serum or in assay diluent were within the range of 85-110%. The Elecsys SHBG assay correlated well (r=0.98) with the SHBG immunoradiometric assay, but values were higher for the Elecsys assay (Passing Bablok regression analysis: slope 1.14, intercept +2.5). In healthy subjects and clinical subgroups, we confirmed the differences in SHBG values reported in the literature. The Elecsys SHBG immunoassay provides precision and reliability in combination with reduced turnaround time.

MeSH Terms
Contraceptives, Oral, Hormonal/blood Electrochemistry Female Hormone Replacement Therapy Humans Hyperthyroidism/blood Hypothyroidism/blood Immunoassay/instrumentation,methods,statistics & numerical data Luminescent Measurements/instrumentation,methods,statistics & numerical data Male Pregnancy Radioimmunoassay/statistics & numerical data Regression Analysis Reproducibility of Results Sensitivity and Specificity Sex Factors Sex Hormone-Binding Globulin/analysis
Chemicals
Contraceptives, Oral, Hormonal Sex Hormone-Binding Globulin
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Reynders Marijke
Radioimmunology Laboratory, Dutch-speaking Free University Brussels, Brussels, Belgium.
Anckaert Ellen
Schiettecatte Johan
Smitz Johan
Article Info
Journal
Clinical chemistry and laboratory medicine
Abbr.
Clin Chem Lab Med
ISSN
1434-6621
Published
2005-00-00
Pages
86-9
Language
English
Region
Germany
NLM ID
9806306
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]