Abstract
This case study of a serious medication error demonstrates the necessity of a comprehensive methodology for the analysis of failures in interaction between humans and information systems. The authors used a novel approach to analyze a dosing error related to computer-based ordering of potassium chloride (KCl). The method included a chronological reconstruction of events and their interdependencies from provider order entry usage logs, semistructured interviews with involved clinicians, and interface usability inspection of the ordering system. Information collected from all sources was compared and evaluated to understand how the error evolved and propagated through the system. In this case, the error was the product of faults in interaction among human and system agents that methods limited in scope to their distinct analytical domains would not identify. The authors characterized errors in several converging aspects of the drug ordering process: confusing on-screen laboratory results review, system usability difficulties, user training problems, and suboptimal clinical system safeguards that all contributed to a serious dosing error. The results of the authors' analysis were used to formulate specific recommendations for interface layout and functionality modifications, suggest new user alerts, propose changes to user training, and address error-prone steps of the KCl ordering process to reduce the risk of future medication dosing errors.
MeSH Terms
Aged
Clinical Pharmacy Information Systems
Hospital Information Systems
Humans
Medical Records Systems, Computerized
Medication Errors
Medication Systems, Hospital
Organizational Case Studies
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Horsky Jan
Laboratory of Decision Making and Cognition, Department of Biomedical Informatics, Columbia University, 622 West 168th Street, Vanderbilt Clinic, 5th Floor, New York, NY 10032-3720, USA.
[email protected]
Kuperman Gilad J
Patel Vimla L
References (24)
24 references, click to expand
-
Re-engineering the medication error-reporting process: removing the blame and improving the system.
Am J Health Syst Pharm. 2000 Dec 15;57 Suppl 4:S10-7
PMID: 11148939
-
Patient Safety Leadership WalkRounds.
Jt Comm J Qual Saf. 2003 Jan;29(1):16-26
PMID: 12528570
-
A framework for analyzing the cognitive complexity of computer-assisted clinical ordering.
J Biomed Inform. 2003 Feb-Apr;36(1-2):4-22
PMID: 14552843
-
Using usability heuristics to evaluate patient safety of medical devices.
J Biomed Inform. 2003 Feb-Apr;36(1-2):23-30
PMID: 14552844
-
Usability in the real world: assessing medical information technologies in patients' homes.
J Biomed Inform. 2003 Feb-Apr;36(1-2):45-60
PMID: 14552846
-
The cognitive complexity of a provider order entry interface.
AMIA Annu Symp Proc. 2003;:294-8
PMID: 14728181
-
Cognitive and usability engineering methods for the evaluation of clinical information systems.
J Biomed Inform. 2004 Feb;37(1):56-76
PMID: 15016386
-
Computer physician order entry and the real world: we're only humans.
Jt Comm J Qual Saf. 2004 Jun;30(6):342-6
PMID: 15208984
-
Medication prescribing errors in a teaching hospital.
JAMA. 1990 May 2;263(17):2329-34
PMID: 2325234
-
Incidence and preventability of adverse drug events in hospitalized adults.
J Gen Intern Med. 1993 Jun;8(6):289-94
PMID: 8320571
-
Does housestaff discontinuity of care increase the risk for preventable adverse events?
Ann Intern Med. 1994 Dec 1;121(11):866-72
PMID: 7978700
-
Assessment of a computerized patient record system: a cognitive approach to evaluating medical technology.
MD Comput. 1996 Sep-Oct;13(5):406-15
PMID: 8824101
-
Adverse drug events in hospitalized patients. Excess length of stay, extra costs, and attributable mortality.
JAMA. 1997 Jan 22-29;277(4):301-6
PMID: 9002492
-
Using computerized data to identify adverse drug events in outpatients.
J Am Med Inform Assoc. 2001 May-Jun;8(3):254-66
PMID: 11320070
-
Reducing the frequency of errors in medicine using information technology.
J Am Med Inform Assoc. 2001 Jul-Aug;8(4):299-308
PMID: 11418536
-
Patient safety and computerized medication ordering at Brigham and Women's Hospital.
Jt Comm J Qual Improv. 2001 Oct;27(10):509-21
PMID: 11593885
-
Applying human factors to the design of medical equipment: patient-controlled analgesia.
J Clin Monit Comput. 1998 May;14(4):253-63
PMID: 9754614
-
Interface design for health care environments: the role of cognitive science.
Proc AMIA Symp. 1998;:29-37
PMID: 9929179
-
Decision support for medication use in an inpatient physician order entry application and a pharmacy application.
Stud Health Technol Inform. 1998;52 Pt 1:467-71
PMID: 10384500
-
The impact of computerized physician order entry on medication error prevention.
J Am Med Inform Assoc. 1999 Jul-Aug;6(4):313-21
PMID: 10428004
-
Guided medication dosing for inpatients with renal insufficiency.
JAMA. 2001 Dec 12;286(22):2839-44
PMID: 11735759
-
Ecological interface design: progress and challenges.
Hum Factors. 2002 Spring;44(1):62-78
PMID: 12118874
-
Information technology and medication safety: what is the benefit?
Qual Saf Health Care. 2002 Sep;11(3):261-5
PMID: 12486992
-
Linking laboratory and pharmacy: opportunities for reducing errors and improving care.
Arch Intern Med. 2003 Apr 28;163(8):893-900
PMID: 12719197