Combining SPECT medical imaging and computational fluid dynamics for analyzing blood and dialysate flow in hemodialyzers.

The International journal of artificial organs ·Vol. 28 ·No. 7 ·2005-07-00 ·页码 739-49

Eloot S, D'Asseler Y, De Bondt P, Verdonck R

Abstract

For a better insight in dialyzer efficiency with respect to local mass transport in a low flux dialyzer (Fresenius F6HPS), blood and dialysate flow distributions were visualized with computational fluid dynamic (CFD) simulations, which were validated with single photon emission computed tomography (SPECT) imaging. To visualize blood-side flow while avoiding transport through the fiber membrane, a bolus of 99m-Technetium labeled MAA (Macro Aggregated Albumin) was injected in the flow using an electronic valve. Water was used to simulate blood, but flow rate was adjusted according to laws of dynamic similarity to account for the viscosity difference (factor 2.75). For the visualization of dialysate flow, a bolus of 99m-Technetium labeled DMSA (Dimercaptosuccinic Acid) was injected, while pressurized air in the blood compartment avoided transmembrane flow. For each test series, 3D acquisitions were made on a two respectively three-headed SPECT camera. By evaluating the images at different time steps, dynamic 3D intensity plots were obtained, which were further used to derive local flow velocities. Additionally, three-dimensional CFD models were developed for simulating the overall blood and dialysate flow, respectively. In both models,the whole fiber compartment was defined as a porous medium with overall axial and radial permeability derived theoretically and from in vitro tests. With the imaging as well as with the computational technique, a homogeneous blood flow distribution was found, while vortices and fluid stagnation were observed in the dialyzer inlet manifold. The non-homogeneous dialysate distribution, as found with SPECT imaging, implies the occurrence of non-efficient sites with respect to mass transfer. The discrepancy between the dialysate results of both techniques indicated that the assumption of a constant fiber bundle permeability in the CFD model was too optimistic. In conclusion, medical imaging techniques like SPECT are very helpful to validate CFD models, which can be further applied for dialyzer design and optimization.

MeSH 主题词
Blood Flow Velocity/physiology Computational Biology Fluid Shifts Hemodialysis Solutions/pharmacokinetics Hemorheology/methods Humans Models, Biological Regional Blood Flow/physiology Renal Dialysis Tomography, Emission-Computed, Single-Photon
化学物质
Hemodialysis Solutions
作者与单位
共 4 位作者,点击展开单位 / ORCID
Eloot S
Hydraulics Laboratory, Institute for Biomedical Technology, Ghent University, Gent, Belgium. [email protected]
D'Asseler Y
De Bondt P
Verdonck R
Article Info
Journal
The International journal of artificial organs
Abbr.
Int J Artif Organs
ISSN
0391-3988
Corresponding email
Published
2005-07-00
页码
739-49
Language
English
Country/Region
United States
NLM ID
7802649
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]