Home LiteratureArticle Details
PMID: 16906573 Published · ppublish English Comparative Study Journal Article

ZAP-70 by flow cytometry: a comparison of different antibodies, anticoagulants, and methods of analysis.

Cytometry. Part B, Clinical cytometry ·Vol. 70 ·No. 4 ·2006-07-15 ·Pages 235-41

Best OG, Ibbotson RE, Parker AE, Davis ZA, Orchard JA, Oscier DG

Abstract

The clinical course of chronic lymphocytic leukaemia (CLL) is variable. ZAP-70 expression is believed to provide prognostic information. The flow cytometric detection of ZAP-70 is difficult because it is an intracellular antigen with weak expression in CLL. Consensus has not been reached as to the best method for measurement. We analyzed 72 CLL patient samples for ZAP-70 expression and IgVH mutational status. Sensitivity and specificity of ZAP-70 expression against IgVH mutational status were assessed for two clones (2F3.2 and 1E7.2) and for four methods of analysis: percentage positivity (PP), comparing test to isotype control, ratio of geometric means of test and isotype control, and percentage and ratiometric methods comparing test and T/NK cell populations. The effects of anticoagulant, collection times, and time to analysis were also evaluated. Sensitivity and specificity were 85 and 88%, respectively, for Upstate PP; 70 and 88% for Caltag PP; 89 and 91% for Upstate ratio; 89 and 88% for Caltag ratio. Intraobserver variability was smaller when ZAP-70 expression was assessed using a ratiometric approach rather than the percentage method. By 48 h, we observed an average decrease of 13% in the Caltag ratio in the heparin preserved samples compared to an increase of 3% in those collected in EDTA. Within the first 24-h period, a greater percent variability was observed in those samples collected into EDTA compared with heparin. Our data support a rapid method for ZAP-70 measurement using commercially available fixation/permeabilization reagents, a conjugated antibody, and a ratiometric method of analysis that minimizes subjective interpretation of the results. This is a method of ZAP-70 assessment that could be included in a routine diagnostic CLL panel; however, the choice of anticoagulant and time of analysis after collection are critical factors in accurate assessment of ZAP-70 expression.

MeSH Terms
Antibodies/immunology Anticoagulants/pharmacology Antigen-Antibody Reactions Biomarkers, Tumor/analysis,chemistry,immunology Disease Progression Flow Cytometry/methods Humans Immunoglobulin Heavy Chains/genetics Immunoglobulin Variable Region/genetics Leukemia, Lymphocytic, Chronic, B-Cell/diagnosis,genetics,metabolism Middle Aged Mutation Reproducibility of Results Sensitivity and Specificity Staining and Labeling Time Factors ZAP-70 Protein-Tyrosine Kinase/analysis,drug effects,immunology
Chemicals
Antibodies Anticoagulants Biomarkers, Tumor Immunoglobulin Heavy Chains Immunoglobulin Variable Region ZAP-70 Protein-Tyrosine Kinase ZAP70 protein, human
Authors & Affiliations
6 authors, click to expand affiliations / ORCID
Best O G
Ibbotson R E
Parker A E
Davis Z A
Orchard J A
Oscier D G
Article Info
Journal
Cytometry. Part B, Clinical cytometry
Abbr.
Cytometry B Clin Cytom
ISSN
1552-4949
Published
2006-07-15
Pages
235-41
Language
English
Region
United States
NLM ID
101235690
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]