The effect of hydration status on the echocardiographic measurements of normal cats.

Journal of veterinary internal medicine ·Vol. 21 ·No. 5 ·2007-00-00 ·页码 1008-15

Campbell FE, Kittleson MD

Abstract

Diagnosis of cardiomyopathy of cats is based on 2-dimensional (2D) echocardiography. However, circulating fluid volume largely determines diastolic cardiac chamber dimensions, and reduced diastolic volume in other species results in what has been called "pseudohypertrophy of the ventricular myocardium." Altered hydration produces changes on 2D echocardiography that may confound the diagnosis or severity assessment of cardiomyopathy of cats. Ten normal colony-sourced mixed breed cats were included. Cats were examined by echocardiography at baseline and at completion of 3 protocols (volume depletion and maintenance-rate and anesthetic-rate IV fluid administration) applied in randomized crossover design with a 6-7 day washout period. Volume depletion increased diastolic left ventricular interventricular septal (IVSd) and free wall diameter (4.5 +/- 0.4 to 5.8 +/- 0.6 mm; P < .001) with wall thickness exceeding 6 mm in 4 cats. Diastolic left ventricular internal diameter (LVIDd) decreased, and reduction in systolic left ventricular internal diameter (LVIDs) produced end-systolic cavity obliteration in 7 cats. Left-atrial-to-aortic-root ratio (LA: Ao, 1.4 +/- 0.2 to 1.2 +/- 0.1, P < .05) and left atrial area in diastole (LAAd) decreased with volume depletion. Maintenance-rate IV fluid administration increased LAAd and fractional shortening (FS%). Anesthetic-rate IV fluid administration increased LVIDd, FS%, LAAd, and LA:Ao ratios (to 1.7 +/- 0.1, P < .01), producing an LA: Ao ratio above normal limits in 6 cats. A systolic heart murmur developed with administration of fluid at maintenance (n = 1) and anesthetic rates (n = 6). Altered hydration status produces changes in the echocardiographic examination of normal cats that may lead to an erroneous diagnosis of cardiomyopathy or mask its presence. Hydration status should be considered during echocardiographic examination in cats.

MeSH 主题词
Animals Blood Proteins/metabolism Cardiomyopathies/diagnostic imaging,veterinary Cat Diseases/diagnostic imaging Cats/metabolism Cross-Over Studies Dehydration/diagnostic imaging,veterinary Diuretics/pharmacology Echocardiography, Doppler/methods,veterinary Female Furosemide/pharmacology Heart Rate/physiology Hematocrit/veterinary Male Random Allocation
化学物质
Blood Proteins Diuretics Furosemide
作者与单位
共 2 位作者,点击展开单位 / ORCID
Campbell F E
Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, CA, USA. [email protected]
Kittleson M D
Article Info
Journal
Journal of veterinary internal medicine
Abbr.
J Vet Intern Med
ISSN
0891-6640
Corresponding email
Published
2007-00-00
页码
1008-15
Language
English
Country/Region
United States
NLM ID
8708660
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]