Home LiteratureArticle Details
PMID: 17993491 Published · ppublish English Evaluation Study Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

Evaluating intramural virtual electrodes in the myocardial wedge preparation: simulations of experimental conditions.

Biophysical journal ·Vol. 94 ·No. 5 ·2008-03-01 ·Pages 1904-15

Plank G, Prassl A, Hofer E, Trayanova NA

Abstract

While defibrillation is the only means for prevention of sudden cardiac death, key aspects of the process, such as the intramural virtual electrodes (VEs), remain controversial. Experimental studies had attempted to assess intramural VEs by using wedge preparations and recording activity from the cut surface; however, applicability of this approach remains unclear. These studies found, surprisingly, that for strong shocks, the entire cut surface was negatively polarized, regardless of boundary conditions. The goal of this study is to examine, by means of bidomain simulations, whether VEs on the cut surface represent a good approximation to VEs in depth of the intact wall. Furthermore, we aim to explore mechanisms that could give rise to negative polarization on the cut surface. A model of wedge preparation was used, in which fiber orientation could be changed, and where the cut surface was subjected to permeable and impermeable boundary conditions. Small-scale mechanisms for polarization were also considered. To determine whether any distortions in the recorded VEs arise from averaging during optical mapping, a model of fluorescent recording was employed. The results indicate that, when an applied field is spatially uniform and impermeable boundary conditions are enforced, regardless of the fiber orientation VEs on the cut surface faithfully represent those intramurally, provided tissue properties are not altered by dissection. Results also demonstrate that VEs are sensitive to the conductive layer thickness above the cut surface. Finally, averaging during fluorescent recordings results in large negative VEs on the cut surface, but these do not arise from small-scale heterogeneities.

MeSH Terms
Action Potentials/physiology Algorithms Animals Computer Simulation Death, Sudden, Cardiac/prevention & control Electric Countershock/instrumentation,methods Electrodes Electrophysiology Heart Conduction System/metabolism,pathology Microscopy, Fluorescence Models, Cardiovascular Myocardial Contraction/physiology Myocardium/metabolism,pathology Swine Ventricular Fibrillation/pathology,prevention & control,therapy
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Plank G
Center for Physiological Medicine, Institute or Biophysics, Medical University Graz, Graz, Austria.
Prassl A
Hofer E
Trayanova N A
References (36)
36 references, click to expand
  1. Role of intramural virtual electrodes in shock-induced activation of left ventricle: optical measurements from the intact epicardial surface.
    Heart Rhythm. 2006 Sep;3(9):1063-73 PMID: 16945803
  2. Development of an optrode for intramural multisite optical recordings of Vm in the heart.
    J Cardiovasc Electrophysiol. 2003 Nov;14(11):1196-202 PMID: 14678134
  3. Virtual electrode effects in transvenous defibrillation-modulation by structure and interface: evidence from bidomain simulations and optical mapping.
    J Cardiovasc Electrophysiol. 1998 Sep;9(9):949-61 PMID: 9786075
  4. Optical transmembrane potential measurements during defibrillation-strength shocks in perfused rabbit hearts.
    Circ Res. 1995 Sep;77(3):593-602 PMID: 7641329
  5. Virtual electrodes in cardiac tissue: a common mechanism for anodal and cathodal stimulation.
    Biophys J. 1995 Dec;69(6):2195-210 PMID: 8599628
  6. Effects of the tissue-bath interface on the induced transmembrane potential: a modeling study in cardiac stimulation.
    Ann Biomed Eng. 1997 Sep-Oct;25(5):783-92 PMID: 9300102
  7. Differences between left and right ventricular chamber geometry affect cardiac vulnerability to electric shocks.
    Circ Res. 2005 Jul 22;97(2):168-75 PMID: 15976315
  8. Algebraic multigrid preconditioner for the cardiac bidomain model.
    IEEE Trans Biomed Eng. 2007 Apr;54(4):585-96 PMID: 17405366
  9. The role of cardiac tissue structure in defibrillation.
    Chaos. 1998 Mar;8(1):221-233 PMID: 12779723
  10. Defibrillation of the heart: insights into mechanisms from modelling studies.
    Exp Physiol. 2006 Mar;91(2):323-37 PMID: 16469820
  11. Nonlinear changes of transmembrane potential caused by defibrillation shocks in strands of cultured myocytes.
    Am J Physiol Heart Circ Physiol. 2000 Mar;278(3):H688-97 PMID: 10710335
  12. Defibrillation depends on conductivity fluctuations and the degree of disorganization in reentry patterns.
    J Cardiovasc Electrophysiol. 2005 Feb;16(2):205-16 PMID: 15720461
  13. Patterns of and mechanisms for shock-induced polarization in the heart: a bidomain analysis.
    IEEE Trans Biomed Eng. 1999 Mar;46(3):260-70 PMID: 10097461
  14. Asymmetry in membrane responses to electric shocks: insights from bidomain simulations.
    Biophys J. 2004 Oct;87(4):2271-82 PMID: 15454429
  15. Dynamic changes in conduction velocity and gap junction properties during development of pacing-induced heart failure.
    Am J Physiol Heart Circ Physiol. 2007 Aug;293(2):H1223-30 PMID: 17434978
  16. LabHEART: an interactive computer model of rabbit ventricular myocyte ion channels and Ca transport.
    Am J Physiol Cell Physiol. 2001 Dec;281(6):C2049-60 PMID: 11698264
  17. Discrete versus syncytial tissue behavior in a model of cardiac stimulation--II: Results of simulation.
    IEEE Trans Biomed Eng. 1996 Dec;43(12):1141-50 PMID: 9214833
  18. The induction of reentry in cardiac tissue. The missing link: How electric fields alter transmembrane potential.
    Chaos. 1998 Mar;8(1):204-220 PMID: 12779722
  19. The role of photon scattering in optical signal distortion during arrhythmia and defibrillation.
    Biophys J. 2007 Nov 15;93(10):3714-26 PMID: 17978166
  20. Intramural multisite recording of transmembrane potential in the heart.
    Biophys J. 2001 Nov;81(5):2671-80 PMID: 11606280
  21. Blinded validation of the isolated arterially perfused rabbit ventricular wedge in preclinical assessment of drug-induced proarrhythmias.
    Heart Rhythm. 2006 Aug;3(8):948-56 PMID: 16876745
  22. A generalized activating function for predicting virtual electrodes in cardiac tissue.
    Biophys J. 1997 Sep;73(3):1410-23 PMID: 9284308
  23. Nonlinear changes of transmembrane potential during defibrillation shocks: role of Ca(2+) current.
    Circ Res. 2000 Sep 15;87(6):453-9 PMID: 10988236
  24. Amplified transmural dispersion of repolarization as the basis for arrhythmogenesis in a canine ventricular-wedge model of short-QT syndrome.
    Circulation. 2004 Dec 14;110(24):3661-6 PMID: 15569843
  25. Examination of optical depth effects on fluorescence imaging of cardiac propagation.
    Biophys J. 2003 Dec;85(6):4134-45 PMID: 14645100
  26. Synthesis of voltage-sensitive optical signals: application to panoramic optical mapping.
    Biophys J. 2006 Apr 15;90(8):2938-45 PMID: 16443665
  27. Nonlinear changes of transmembrane potential during electrical shocks: role of membrane electroporation.
    Circ Res. 2004 Feb 6;94(2):208-14 PMID: 14670844
  28. Roles of electric field and fiber structure in cardiac electric stimulation.
    Biophys J. 1999 Sep;77(3):1404-17 PMID: 10465752
  29. Responses of the transmembrane potential of myocardial cells during a shock.
    J Cardiovasc Electrophysiol. 1995 Apr;6(4):252-63 PMID: 7647950
  30. Differences between left and right ventricular anatomy determine the types of reentrant circuits induced by an external electric shock. A rabbit heart simulation study.
    Prog Biophys Mol Biol. 2006 Jan-Apr;90(1-3):399-413 PMID: 16055175
  31. Intramural virtual electrodes in ventricular wall: effects on epicardial polarizations.
    Circulation. 2004 May 18;109(19):2349-56 PMID: 15117837
  32. The effect of the cut surface during electrical stimulation of a cardiac wedge preparation.
    IEEE Trans Biomed Eng. 2006 Jun;53(6):1187-90 PMID: 16761846
  33. Diastolic shocking experience: do virtual electrodes exist only during systole?
    J Cardiovasc Electrophysiol. 2003 Nov;14(11):1223-4 PMID: 14678139
  34. Intramural virtual electrodes during defibrillation shocks in left ventricular wall assessed by optical mapping of membrane potential.
    Circulation. 2002 Aug 20;106(8):1007-14 PMID: 12186808
  35. Optical mapping of transmural activation induced by electrical shocks in isolated left ventricular wall wedge preparations.
    J Cardiovasc Electrophysiol. 2003 Nov;14(11):1215-22 PMID: 14678138
  36. High-resolution optical mapping of intramural virtual electrodes in porcine left ventricular wall.
    Cardiovasc Res. 2004 Dec 1;64(3):448-56 PMID: 15537498
Article Info
Journal
Biophysical journal
Abbr.
Biophys J
ISSN
1542-0086
Published
2008-03-01
Epub
2007-00-09
Pages
1904-15
Language
English
Region
United States
NLM ID
0370626
PMCID
PMC2242738
Subset
IM
Grants
NHLBI NIH HHS · R01 HL063195 · United States
NHLBI NIH HHS · HL063195 · United States
NHLBI NIH HHS · R01 HL082729 · United States
Austrian Science Fund FWF · F 3210 · Austria
NHLBI NIH HHS · HL082729 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]