Home LiteratureArticle Details
PMID: 18175019 Published · ppublish English Journal Article Research Support, U.S. Gov't, Non-P.H.S.

Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft.

Journal of environmental monitoring : JEM ·Vol. 10 ·No. 1 ·2008-01-00 ·页码 71-81

Mazumdar S, Chen Q

Abstract

Potential causalities due to airborne disease transmission and risk of chem-bio terrorism in commercial airliner cabins can be reduced by fast responses. Fast responses are only possible by using sensors at appropriate locations in the cabins. Cost, size and weight factors restrict the number of sensors that could be installed inside a cabin. Since release locations and seating patterns of passengers can impact airborne contaminant transports, this study first addressed this impact by using a validated computational fluid dynamics (CFD) program in a four-row mockup of twin-aisle airliner cabin. It was observed that occupancy patterns and release locations have little influence on longitudinal contaminant transports though localized variations of contaminant concentrations may exist. The results show that response time of the sensors is considerably reduced with the increase in number of sensors. If only a single sensor is available across a cabin cross-section then it should be placed at the middle of the ceiling. A cabin model of a fully occupied twin-aisle airliner with 210 seats was also build to study the diverse contaminant distribution trends along cabin length. The results reveal that seating arrangements can make cross-sectional airflow pattern considerably asymmetrical. Similar airflow patterns make the longitudinal contaminant transport in the business and economy classes alike. The presence of galleys greatly affected the longitudinal transport of contaminants in a particular cabin section. The effects due to galleys were less significant if a multipoint sampling system was used. The multipoint sampling system can also reduce the number of sensors required in a cabin.

MeSH 主题词
Air Movements Air Pollutants/analysis Air Pollution, Indoor/analysis Aircraft Environmental Monitoring/methods Temperature
化学物质
Air Pollutants
作者与单位
共 2 位作者,点击展开单位 / ORCID
Mazumdar Sagnik
Air Transportation Center of Excellence for Airliner Cabin Environment Research, School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907-2088, USA.
Chen Qingyan
Article Info
Journal
Journal of environmental monitoring : JEM
Abbr.
J Environ Monit
ISSN
1464-0325
Published
2008-01-00
电子出版
2007-00-03
页码
71-81
Language
English
Country/Region
England
NLM ID
100968688
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]