Home LiteratureArticle Details
PMID: 18297492 Published · ppublish English Journal Article

Three-dimensional cerebrospinal fluid flow within the human ventricular system.

Computer methods in biomechanics and biomedical engineering ·Vol. 11 ·No. 2 ·2008-04-00 ·页码 123-33

Howden L, Giddings D, Power H, Aroussi A, Vloeberghs M, Garnett M, Walker D

Abstract

Cerebrospinal fluid (CSF) is a Newtonian fluid and can, therefore, be modelled using computational fluid dynamics (CFD). Previous modelling of the CSF has been limited to simplified geometric models. This work describes a geometrically accurate three dimensional (3D) computational model of the human ventricular system (HVS) constructed from magnetic resonance images (MRI) of the human brain. It is an accurate and full representation of the HVS and includes appropriately positioned CSF production and drainage locations. It was used to investigate the pulsatile motion of CSF within the human brain. During this investigation CSF flow rate was set at a constant 500 ml/day, to mimic real life secretion of CSF into the system, and a pulsing velocity profile was added to the inlets to incorporate the effect of cardiac pulsations on the choroid plexus and their subsequent influence on CSF motion in the HVS. Boundary conditions for the CSF exits from the ventricles (foramina of Magendie and Lushka) were found using a "nesting" approach, in which a simplified model of the entire central nervous system (CNS) was used to examine the effects of the CSF surrounding the ventricular system (VS). This model provided time varying pressure data for the exits from the VS nested within it. The fastest flow was found in the cerebral aqueduct, where a maximum velocity of 11.38 mm/s was observed over five cycles. The maximum Reynolds number recorded during the simulation was 15 with an average Reynolds number of the order of 0.39, indicating that CSF motion is creeping flow in most of the computational domain and consequently will follow the geometry of the model. CSF pressure also varies with geometry with a maximum pressure drop of 1.14 Pa occurring through the cerebral aqueduct. CSF flow velocity is substantially slower in the areas that are furthest away from the inlets; in some areas flow is nearly stagnant.

MeSH 主题词
Cerebrospinal Fluid/physiology Computer Simulation Humans Imaging, Three-Dimensional/methods Models, Biological Rheology/methods Ventricular Function
作者与单位
共 7 位作者,点击展开单位 / ORCID
Howden L
School of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, Nottingham, UK.
Giddings D
Power H
Aroussi A
Vloeberghs M
Garnett M
Walker D
Article Info
Journal
Computer methods in biomechanics and biomedical engineering
Abbr.
Comput Methods Biomech Biomed Engin
ISSN
1025-5842
Published
2008-04-00
页码
123-33
Language
English
Country/Region
England
NLM ID
9802899
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]