Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD.

Karmonik C, Klucznik R, Benndorf G

Abstract

Computational Fluid Dynamic (CFD) is increasingly being used for modeling hemodynamics in intracranial aneurysms. While CFD techniques are well established, need for validation of the results remains. By quantifying features in velocity patterns measured with 2D phase contrast magnetic resonance (pcMRI) in vivo and simulated with CFD, the role of pcMRI for providing reference data for the CFD simulation is explored. Unsteady CFD simulations were performed with inflow boundary conditions obtained from 2D pcMRI measurements of an aneurysm of the anterior communication artery. Intra-aneurysmal velocity profiles were recorded with 2D pcMRI and calculated with CFD. Relative areas of positive and negative velocity were calculated in these profiles for maximum and minimum inflow. Areas of positive and of negative velocity similar in shape were found in the velocity profiles obtained with both methods. Relative difference in size of the relative areas for the whole cardiac cycle ranged from 1%-25% (average 12%). 2D pcMRI is able to record velocity profiles in an aneurysm of the anterior commuting artery in vivo. These velocity profiles can serve as reference data for validation of CFD simulations. Further studies are needed to explore the role of pcMRI in the context of CFD simulations.

MeSH 主题词
Blood Flow Velocity Cerebral Arteries/physiopathology Cerebrovascular Circulation Computer Simulation Hemodynamics Humans Intracranial Aneurysm/physiopathology Magnetic Resonance Angiography
作者与单位
共 3 位作者,点击展开单位 / ORCID
Karmonik Christof
Department of Radiology, The Methodist Hospital Research Institute, Houston, TX, USA. [email protected]
Klucznik Richard
Benndorf Goetz
Article Info
Journal
Technology and health care : official journal of the European Society for Engineering and Medicine
Abbr.
Technol Health Care
ISSN
0928-7329
Corresponding email
Published
2008-00-00
页码
119-28
Language
English
Country/Region
Netherlands
NLM ID
9314590
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]