Disinfection practices for endoscopes and other semicritical items.

Infection control and hospital epidemiology ·Vol. 12 ·No. 5 ·1991-05-00 ·Pages 282-8

Rutala WA, Clontz EP, Weber DJ, Hoffmann KK

Abstract

To determine the disinfection practices employed by North Carolina hospitals for endoscopes and other semicritical patient care items and to discuss minimally acceptable disinfection procedures for these items. A survey questionnaire was mailed to all North Carolina hospitals to identify their disinfection practices, and a literature review was conducted to ascertain studies that evaluated disinfection techniques for certain semicritical items. Questionnaires were returned by 107 of 167 (64%) North Carolina acute-care hospitals. Most hospitals (91%) used a glutaraldehyde-based disinfectant (59%, 2% glutaraldehyde; 29%, 0.13% glutaraldehyde-0.44% phenol-0.08% phenate; 3%, either); half (51%) of the hospitals immersed the endoscope into disinfectant for greater than or equal to 20 minutes, but 44% immersed for less than or equal to 10 minutes; nearly all hospitals (97%) disinfected endoscopes at room temperature. Hospitals rinsed the endoscope with sterile water (16%), tap water (54%), tap water followed by alcohol rinse (27%), or other (2%); 58% of the hospitals treated endoscopes from patients infected with human immunodeficiency virus (HIV), hepatitis B virus (HBV), or Mycobacterium tuberculosis differently (81%, ethylene oxide [ETO] sterilization; 10%, increased exposure time; 10%, other). Twenty percent of the hospitals used an automated washer for processing endoscopic instruments. Rigid endoscopes (e.g., arthroscopes, laparoscopes) were primarily high-level disinfected (57%), ETO sterilized (17%), or either (13%). The disinfection strategies for other semi-critical items (e.g., applanation tonometers, cryosurgical instruments, and diaphragm fitting rings) were highly variable for the responding hospitals. This survey indicated the presence of a wide variety of practices for handling semicritical patient care items, many of which are inconsistent with current recommendations. To help establish minimally acceptable disinfection procedures for some patient care instruments (e.g., arthroscopes, laparoscopes, tonometers), the scientific literature was reviewed and recommendations were made.

MeSH Terms
Disinfection/methods,standards Endoscopes Endoscopy/classification Glutaral Health Knowledge, Attitudes, Practice Hospitals/classification Humans North Carolina Surveys and Questionnaires Time Factors
Chemicals
Glutaral
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Rutala W A
Department of Medicine, University of North Carolina (UNC) School of Medicine, Chapel Hill 27599-7030.
Clontz E P
Weber D J
Hoffmann K K
Article Info
Journal
Infection control and hospital epidemiology
Abbr.
Infect Control Hosp Epidemiol
ISSN
0899-823X
Published
1991-05-00
Pages
282-8
Language
English
Region
United States
NLM ID
8804099
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]