Home LiteratureArticle Details
PMID: 19250915 Published · ppublish English Journal Article

Automated immunoassay system for AFP-L3% using on-chip electrokinetic reaction and separation by affinity electrophoresis.

Analytical biochemistry ·Vol. 388 ·No. 2 ·2009-05-15 ·Pages 306-11

Kagebayashi C, Yamaguchi I, Akinaga A, Kitano H, Yokoyama K, Satomura M, Kurosawa T, Watanabe M, Kawabata T, Chang W, Li C, Bousse L, Wada HG, Satomura S

Abstract

Implementation of the on-chip immunoassay for alpha-fetoprotein (AFP)-L3% was achieved using a fully automated microfluidic instrument platform that will prepare the chip and run the assay with a total assay time of less than 10min. Reagent/sample mixing, concentration, and reaction in microfluidic channels occur by the electrokinetic analyte transport assay (EATA) technique, enabling the integration of all assay steps on-chip. The determination of AFP-L3%, a biomarker for hepatocellular carcinoma, was achieved by the presence of Lens culinaris agglutinin in the separation channel, causing separation of the fucosylated isoform, AFP-L3, from the nonfucosylated AFP-L1 by lectin affinity electrophoresis. Laser-induced-fluorescence (LIF) detection was used to quantitate the labeled immunocomplexes. The limit of detection (LOD) was 0.1ng/ml AFP, and assay precision of less than 2% coefficient of variation (CV) was obtained for quantitation from 24 to 922ng/ml total AFP in spiked serum samples. Assay precision of less than 3% CV was obtained for AFP-L3% measurements from 8.5 to 81%. Furthermore, good correlation of test results for 68 patient serum samples with a commercially available reference method (LiBASys assay for AFP-L3%) was obtained, with r(2)=0.981 and slope=1.03.

MeSH Terms
Carcinoma, Hepatocellular/diagnosis Electrophoresis/instrumentation,methods Humans Immunoassay/instrumentation,methods Microfluidic Analytical Techniques Reproducibility of Results alpha-Fetoproteins/analysis
Chemicals
alpha-Fetoproteins
Authors & Affiliations
14 authors, click to expand affiliations / ORCID
Kagebayashi Chiaki
Osaka Research Laboratory, New Diagnostics Business and Technology Development Department, Wako Pure Chemical Industries Ltd., 6-1 Takada-cho, Amagasaki, Hyogo Prefecture, Japan.
Yamaguchi Isao
Akinaga Ayumi
Kitano Hiromichi
Yokoyama Kazunori
Satomura Masahiro
Kurosawa Tatsuo
Watanabe Mitsuo
Kawabata Tomohisa
Chang William
Li Chen
Bousse Luc
Wada Henry G
Satomura Shinji
Article Info
Journal
Analytical biochemistry
Abbr.
Anal Biochem
ISSN
1096-0309
Published
2009-05-15
Epub
2009-00-27
Pages
306-11
Language
English
Region
United States
NLM ID
0370535
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]