Electrokinetic sample injection for high-sensitivity CZE (part 2): improving the quantitative repeatability and application of electrokinetic supercharging-CZE to the detection of atmospheric electrolytes.

Electrophoresis ·Vol. 30 ·No. 20 ·2009-10-00 ·页码 3534-9

Xu Z, Koshimidzu E, Hirokawa T

Abstract

Electrokinetic supercharging (EKS) is defined as a technique that combines electrokinetic sample injection with transient ITP. Quantitative repeatability of EKS-CZE and the other CE methods using electrokinetic sample injection process is usually inferior in comparison with the CE methods using hydrodynamic or hydrostatic injection. This is due to some effects, such as the temperature change and the convection of the sample solution in the reservoir, as well as the change of the distance between an electrode and a capillary end (D(ec)). In particular, we have found that the D(ec) change might most seriously affect the repeatability, especially when the electrode is a thin Pt wire that could be unintentionally bent during sampling. By using a Teflon spacer to fix D(ec) to 1.1 mm, the RSD of peak area (n=5) was decreased from 20 to 3.4% in EKS-CZE for several metal cations. This D(ec) dependence of the sample amount injected was supported by computer simulation using CFD-ACE+ software. The improved repeatability (down to 5.1% at n=5, averaged RSD for Co(2+), Li(+), Ni(2+), Zn(2+) and Pb(2+)) was also experimentally attained by increasing the D(ec) to ca. 20 mm, which was also effective to obtain high sensitivity. Since the temperature and the convection effects on the repeatability are comparatively small in a proper laboratory environment, these effects were estimated from the EKS-CZE experiments using conditions such as warming and agitating the sample solution during EKS process. Finally, EKS-CZE was applied to the detection of ions from atmospheric electrolytes in high-purity water exposed to ambient air for 2 h. The microgram per liter levels of anions (chloride, sulfate, nitrate, formate, acetate and lactate) and cations (ammonium, calcium, sodium and magnesium) could be detected using conventional UV detector.

MeSH 主题词
Air Pollutants/analysis Anions/analysis Cations/analysis Computer Simulation Electrodes Electrolytes/analysis Electrophoresis, Capillary/instrumentation,methods Hydrogen-Ion Concentration Reproducibility of Results Temperature
化学物质
Air Pollutants Anions Cations Electrolytes
作者与单位
共 3 位作者,点击展开单位 / ORCID
Xu Zhongqi
Applied Chemistry, Department of Chemistry and Chemical Engineering, Graduate School of Engineering, Hiroshima University, Japan.
Koshimidzu Eiji
Hirokawa Takeshi
Article Info
Journal
Electrophoresis
Abbr.
Electrophoresis
ISSN
1522-2683
Published
2009-10-00
页码
3534-9
Language
English
Country/Region
Germany
NLM ID
8204476
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]