Home LiteratureArticle Details
PMID: 20126490 Published · ppublish English Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

Patterns of glaucomatous visual field loss in sita fields automatically identified using independent component analysis.

Transactions of the American Ophthalmological Society ·Vol. 107 ·2009-12-00 ·页码 136-44

Goldbaum MH, Jang GJ, Bowd C, Hao J, Zangwill LM, Liebmann J, Girkin C, Jung TP, Weinreb RN, Sample PA

Abstract

To determine if the patterns uncovered with variational Bayesian-independent component analysis-mixture model (VIM) applied to a large set of normal and glaucomatous fields obtained with the Swedish Interactive Thresholding Algorithm (SITA) are distinct, recognizable, and useful for modeling the severity of the field loss. SITA fields were obtained with the Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Inc, Dublin, California) on 1,146 normal eyes and 939 glaucoma eyes from subjects followed by the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. VIM modifies independent component analysis (ICA) to develop separate sets of ICA axes in the cluster of normal fields and the 2 clusters of abnormal fields. Of 360 models, the model with the best separation of normal and glaucomatous fields was chosen for creating the maximally independent axes. Grayscale displays of fields generated by VIM on each axis were compared. SITA fields most closely associated with each axis and displayed in grayscale were evaluated for consistency of pattern at all severities. The best VIM model had 3 clusters. Cluster 1 (1,193) was mostly normal (1,089, 95% specificity) and had 2 axes. Cluster 2 (596) contained mildly abnormal fields (513) and 2 axes; cluster 3 (323) held mostly moderately to severely abnormal fields (322) and 5 axes. Sensitivity for clusters 2 and 3 combined was 88.9%. The VIM-generated field patterns differed from each other and resembled glaucomatous defects (eg, nasal step, arcuate, temporal wedge). SITA fields assigned to an axis resembled each other and the VIM-generated patterns for that axis. Pattern severity increased in the positive direction of each axis by expansion or deepening of the axis pattern. VIM worked well on SITA fields, separating them into distinctly different yet recognizable patterns of glaucomatous field defects. The axis and pattern properties make VIM a good candidate as a preliminary process for detecting progression.

MeSH 主题词
Algorithms Bayes Theorem Diagnostic Techniques, Ophthalmological/instrumentation Glaucoma/diagnosis,physiopathology Humans Models, Statistical Sensitivity and Specificity Severity of Illness Index Visual Fields
作者与单位
共 10 位作者,点击展开单位 / ORCID
Goldbaum Michael H
Department of Ophthalmology, University of California San Diego, USA.
Jang Gil-Jin
Bowd Chris
Hao Jiucang
Zangwill Linda M
Liebmann Jeffrey
Girkin Christopher
Jung Tzyy-Ping
Weinreb Robert N
Sample Pamela A
Article Info
Journal
Transactions of the American Ophthalmological Society
Abbr.
Trans Am Ophthalmol Soc
ISSN
1545-6110
Published
2009-12-00
页码
136-44
Language
English
Country/Region
United States
NLM ID
7506106
基金资助
NEI NIH HHS · EY08208 · United States
NEI NIH HHS · K23 EY013959 · United States
NEI NIH HHS · R01 EY011008 · United States
NEI NIH HHS · EY13928 · United States
NEI NIH HHS · R01 EY011008-14 · United States
NEI NIH HHS · U10 EY014267 · United States
NEI NIH HHS · EY14267 · United States
NEI NIH HHS · EY13959 · United States
NEI NIH HHS · R01 EY008208 · United States
NEI NIH HHS · R21 EY013928 · United States
NEI NIH HHS · R33 EY013928 · United States
NEI NIH HHS · EY11008 · United States
External Links
PubMed source
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]