Home LiteratureArticle Details
PMID: 20346317 Published · ppublish English Comparative Study Journal Article

Value of color Doppler three-dimensional transesophageal echocardiography in the percutaneous closure of mitral prosthesis paravalvular leak.

The American journal of cardiology ·Vol. 105 ·No. 7 ·2010-04-01 ·页码 984-9

Biner S, Kar S, Siegel RJ, Rafique A, Shiota T

Abstract

We investigated the clinical value of three-dimensional (3D) transesophageal echocardiography (TEE) color flow Doppler (TEE-CFD) for percutaneous transcatheter closure of mitral valve prosthesis paravalvular leaks (PVLs) compared to two-dimensional (2D) TEE. The number, location, and size of the mitral valve prosthesis PVLs were determined in 8 patients using 2D and 3D TEE-CFD. We also evaluated 2D and 3D TEE-CFD for identifying the canalization of the target PVL during the intervention and assessing the change in the PVL effective orifice after the endovascular procedure. We visualized 12 PVLs using 2D TEE-CFD and 15 PVLs using 3D TEE-CFD. No substantial disagreement was found between 2D and 3D TEE-CFD for the location for each of the PVLs. No difference was found in the vena contracta short axis width obtained by 2D TEE-CFD and 3D TEE-CFD (5.7 +/- 1.4 mm vs 5.5 +/- 1.3 mm, respectively, p = 0.09). However, only 3D TEE-CFD demonstrated the effective circumferential orifice length of the PVL (12.2 +/- 8.5 mm). A closure device was deployed in 6 cases. In 1 case, the canalization of a nontarget PVL, visualized only on 3D TEE-CFD, led to an appropriate change in the treatment strategy. The reduction in the mean PVL vena contracta width demonstrated using 2D TEE-CFD and 3D TEE-CFD was similar (2.2 +/- 0.7 mm vs 2.1 +/- 1.1 mm, respectively, p = 0.69). However, only 3D TEE-CFD verified the reduction of the effective orifice circumferential length of the PVL by 10.5 +/- 5.6 mm. In conclusion, 3D TEE-CFD provided unique and additive information in patients with mitral valve prosthesis PVLs. This new technology has the potential to improve the procedural success of percutaneous transcatheter closure of PVLs.

MeSH 主题词
Anemia, Hemolytic/etiology Echocardiography, Doppler, Color Echocardiography, Three-Dimensional Echocardiography, Transesophageal Heart Failure/etiology Heart Valve Prosthesis/adverse effects Humans Mitral Valve Prosthesis Failure
作者与单位
共 5 位作者,点击展开单位 / ORCID
Biner Simon
Division of Cardiology, Cedars-Sinai Medical Center, and David Geffen School of Medicine at UCLA, Los Angeles, California, USA.
Kar Saibal
Siegel Robert J
Rafique Asim
Shiota Takahiro
Article Info
Journal
The American journal of cardiology
Abbr.
Am J Cardiol
ISSN
1879-1913
Published
2010-04-01
电子出版
2010-00-13
页码
984-9
Language
English
Country/Region
United States
NLM ID
0207277
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]