Home LiteratureArticle Details
PMID: 21073240 Published · ppublish English Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.

Towards monitoring real-time cellular response using an integrated microfluidics-matrix assisted laser desorption ionisation/nanoelectrospray ionisation-ion mobility-mass spectrometry platform.

IET systems biology ·Vol. 4 ·No. 6 ·2010-11-00 ·Pages 416-27

Enders JR, Marasco CC, Kole A, Nguyen B, Sevugarajan S, Seale KT, Wikswo JP, McLean JA

Abstract

The combination of microfluidic cell trapping devices with ion mobility-mass spectrometry offers the potential for elucidating in real time the dynamic responses of small populations of cells to paracrine signals, changes in metabolite levels and delivery of drugs and toxins. Preliminary experiments examining peptides in methanol and recording the interactions of yeast and Jurkat cells with their superfusate have identified instrumental set-up and control parameters and online desalting procedures. Numerous initial experiments demonstrate and validate this new instrumental platform. Future outlooks and potential applications are addressed, specifically how this instrumentation may be used for fully automated systems biology studies of the significantly interdependent, dynamic internal workings of cellular metabolic and signalling pathways.

MeSH Terms
Cell Biology/instrumentation Cell Physiological Phenomena Cell Separation/instrumentation Cells/chemistry,cytology Humans Jurkat Cells Microfluidic Analytical Techniques/methods Saccharomyces cerevisiae Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods Systems Biology/methods
Authors & Affiliations
8 authors, click to expand affiliations / ORCID
Enders J R
Vanderbilt University, Department of Chemistry, Nashville, TN, USA.
Marasco C C
Kole A
Nguyen B
Sevugarajan S
Seale K T
Wikswo J P
McLean J A
References (48)
48 references, click to expand
  1. Thin-film IrOx pH microelectrode for microfluidic-based microsystems.
    Biosens Bioelectron. 2005 Aug 15;21(2):248-56 PMID: 16023951
  2. Simultaneous glycoproteomics on the basis of structure using ion mobility-mass spectrometry.
    Mol Biosyst. 2009 Nov;5(11):1298-302 PMID: 19823744
  3. Immobilized microfluidic enzymatic reactors.
    Electrophoresis. 2004 Nov;25(21-22):3550-63 PMID: 15565708
  4. The mass-mobility correlation redux: the conformational landscape of anhydrous biomolecules.
    J Am Soc Mass Spectrom. 2009 Oct;20(10):1775-81 PMID: 19646898
  5. Soft lithography in biology and biochemistry.
    Annu Rev Biomed Eng. 2001;3:335-73 PMID: 11447067
  6. Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples.
    Anal Bioanal Chem. 2009 May;394(1):235-44 PMID: 19247641
  7. Microfluidic platform for real-time signaling analysis of multiple single T cells in parallel.
    Lab Chip. 2008 Oct;8(10):1700-12 PMID: 18813394
  8. Integrated plastic microfluidic devices with ESI-MS for drug screening and residue analysis.
    Anal Chem. 2001 May 1;73(9):2048-53 PMID: 11354489
  9. Distilling free-form natural laws from experimental data.
    Science. 2009 Apr 3;324(5923):81-5 PMID: 19342586
  10. Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.
    Anal Chem. 2008 Sep 15;80(18):6881-7 PMID: 18698800
  11. Quantum dot probes for monitoring dynamic cellular response: reporters of T cell activation.
    IEEE Trans Nanobioscience. 2006 Dec;5(4):268-72 PMID: 17181026
  12. Microfluidic single cell arrays to interrogate signalling dynamics of individual, patient-derived hematopoietic stem cells.
    Lab Chip. 2009 Sep 21;9(18):2659-64 PMID: 19704981
  13. The human plasma proteome: history, character, and diagnostic prospects.
    Mol Cell Proteomics. 2002 Nov;1(11):845-67 PMID: 12488461
  14. Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology.
    IEE Proc Nanobiotechnol. 2006 Aug;153(4):81-101 PMID: 16948492
  15. Microfluidic chip for low-flow push-pull perfusion sampling in vivo with on-line analysis of amino acids.
    Anal Chem. 2005 Nov 1;77(21):7067-73 PMID: 16255611
  16. Dual source ion mobility-mass spectrometer for direct comparison of electrospray ionization and MALDI collision cross section measurements.
    Anal Chem. 2010 Apr 15;82(8):3247-54 PMID: 20329759
  17. On-chip acidification rate measurements from single cardiac cells confined in sub-nanoliter volumes.
    Biomed Microdevices. 2008 Jun;10(3):347-54 PMID: 18214684
  18. Gas-phase separations of electrosprayed peptide libraries.
    Anal Chem. 1999 Sep 15;71(18):3918-27 PMID: 10500479
  19. Attomole protein characterization by capillary electrophoresis-mass spectrometry.
    Science. 1996 Aug 30;273(5279):1199-202 PMID: 8703047
  20. An ontology for a Robot Scientist.
    Bioinformatics. 2006 Jul 15;22(14):e464-71 PMID: 16873508
  21. Mass spectrometry-based proteomics.
    Nature. 2003 Mar 13;422(6928):198-207 PMID: 12634793
  22. Shiga toxins present in the gut and in the polymorphonuclear leukocytes circulating in the blood of children with hemolytic-uremic syndrome.
    J Clin Microbiol. 2006 Feb;44(2):313-7 PMID: 16455876
  23. Resilient machines through continuous self-modeling.
    Science. 2006 Nov 17;314(5802):1118-21 PMID: 17110570
  24. High-order structure and dissociation of gaseous peptide aggregates that are hidden in mass spectra.
    J Am Soc Mass Spectrom. 1998 Aug;9(8):743-59 PMID: 9692251
  25. Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies.
    Electrophoresis. 2003 Nov;24(21):3563-76 PMID: 14613181
  26. Mapping the human plasma proteome by SCX-LC-IMS-MS.
    J Am Soc Mass Spectrom. 2007 Jul;18(7):1249-64 PMID: 17553692
  27. Metabolic discrimination of select list agents by monitoring cellular responses in a multianalyte microphysiometer.
    Sensors (Basel). 2009;9(3):2117-33 PMID: 22574003
  28. A microfluidic device to confine a single cardiac myocyte in a sub-nanoliter volume on planar microelectrodes for extracellular potential recordings.
    Lab Chip. 2004 Aug;4(4):357-62 PMID: 15269804
  29. MALDI mass spectrometric imaging of biological tissue sections.
    Mech Ageing Dev. 2005 Jan;126(1):177-85 PMID: 15610777
  30. High-speed, high-resolution monolithic capillary LC-MALDI MS using an off-line continuous deposition interface for proteomic analysis.
    Anal Chem. 2005 Apr 15;77(8):2323-31 PMID: 15828764
  31. Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography.
    J Chromatogr A. 1999 Sep 24;856(1-2):3-54 PMID: 10526783
  32. Online microdialysis-dynamic nanoelectrospray ionization-mass spectrometry for monitoring neuropeptide secretion.
    J Mass Spectrom. 2005 Jul;40(7):924-31 PMID: 15934039
  33. Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay.
    Anal Chem. 2003 Sep 15;75(18):4711-7 PMID: 14674445
  34. Biomolecular structural separations by ion mobility-mass spectrometry.
    Anal Bioanal Chem. 2008 Jun;391(3):905-9 PMID: 18320175
  35. The origins and the future of microfluidics.
    Nature. 2006 Jul 27;442(7101):368-73 PMID: 16871203
  36. Perfusion and chemical monitoring of living cells on a microfluidic chip.
    Lab Chip. 2005 Jan;5(1):56-63 PMID: 15616741
  37. Development of an efficient on-chip digestion system for protein analysis using MALDI-TOF MS.
    Analyst. 2009 Dec;134(12):2426-33 PMID: 19918612
  38. Microfabricated polymer devices for automated sample delivery of peptides for analysis by electrospray ionization tandem mass spectrometry.
    Anal Chem. 1999 Oct 15;71(20):4437-44 PMID: 10546527
  39. Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins.
    J Am Soc Mass Spectrom. 1994 Jul;5(7):605-13 PMID: 24221962
  40. The automation of science.
    Science. 2009 Apr 3;324(5923):85-9 PMID: 19342587
  41. Automated reverse engineering of nonlinear dynamical systems.
    Proc Natl Acad Sci U S A. 2007 Jun 12;104(24):9943-8 PMID: 17553966
  42. Nanoflow LC/ion mobility/CID/TOF for proteomics: analysis of a human urinary proteome.
    J Proteome Res. 2003 Nov-Dec;2(6):589-97 PMID: 14692452
  43. A capillary-PDMS hybrid chip for separations-based sensing of neurotransmitters in vivo.
    Lab Chip. 2006 Sep;6(9):1205-12 PMID: 16929400
  44. Differential pH measurements of metabolic cellular activity in nl culture volumes using microfabricated iridium oxide electrodes.
    Biosens Bioelectron. 2007 Feb 15;22(7):1303-10 PMID: 16860556
  45. A microphysiometer for simultaneous measurement of changes in extracellular glucose, lactate, oxygen, and acidification rate.
    Anal Chem. 2004 Feb 1;76(3):519-27 PMID: 14750842
  46. The chronological life span of Saccharomyces cerevisiae.
    Aging Cell. 2003 Apr;2(2):73-81 PMID: 12882320
  47. Ion mobility-mass spectrometry.
    J Mass Spectrom. 2008 Jan;43(1):1-22 PMID: 18200615
  48. Proteomics. Public projects gear up to chart the protein landscape.
    Science. 2003 Nov 21;302(5649):1316-8 PMID: 14631011
Article Info
Journal
IET systems biology
Abbr.
IET Syst Biol
ISSN
1751-8849
Published
2010-11-00
Pages
416-27
Language
English
Region
England
NLM ID
101301198
PMCID
PMC4254925
Subset
IM
Grants
NIDA NIH HHS · RC2 DA028981 · United States
NIDA NIH HHS · RC2DA028981 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]