Home LiteratureArticle Details
PMID: 21084417 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't Validation Study

Validation of computational fluid dynamics in CT-based airway models with SPECT/CT.

Radiology ·Vol. 257 ·No. 3 ·2010-12-00 ·页码 854-62

De Backer JW, Vos WG, Vinchurkar SC, Claes R, Drollmann A, Wulfrank D, Parizel PM, Germonpré P, De Backer W

Abstract

To compare the results obtained by using numerical flow simulations with the results of combined single photon emission computed tomography (SPECT) and computed tomography (CT) and to demonstrate the importance of correct boundary conditions for the numerical methods to account for the large amount of interpatient variability in airway geometry. This study was approved by all relevant institutional review boards. All patients gave their signed informed consent. In this study, six patients with mild asthma (three men; three women; overall mean age, 46 years ± 17 [standard deviation]) underwent CT at functional residual capacity and total lung capacity, as well as SPECT/CT. CT data were used for segmentation and computational fluid dynamics (CFD) simulations. A comparison was made between airflow distribution, as derived with (a) SPECT/CT through tracer concentration analysis, (b) CT through lobar expansion measurement, and (c) CFD through flow computer simulation. Also, the heterogeneity of the ventilation was examined. Good agreement was found between SPECT/CT, CT, and CFD in terms of airflow distribution and hot spot detection. The average difference for the internal airflow distribution was less than 3% for CFD and CT versus SPECT/CT. Heterogeneity in ventilation patterns could be detected with SPECT/CT and CFD. This results of this study show that patient-specific computer simulations with appropriate boundary conditions yield information that is similar to that obtained with functional imaging tools, such as SPECT/CT. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100322/-/DC1.

MeSH 主题词
Adult Aerosols/administration & dosage Aged Asthma/diagnostic imaging,physiopathology Female Humans Male Middle Aged Models, Anatomic Radiographic Image Interpretation, Computer-Assisted Radiopharmaceuticals/administration & dosage Respiratory Function Tests Software Technetium Tc 99m Pentetate/administration & dosage Tomography, Emission-Computed, Single-Photon Tomography, X-Ray Computed
化学物质
Aerosols Radiopharmaceuticals Technetium Tc 99m Pentetate
作者与单位
共 9 位作者,点击展开单位 / ORCID
De Backer Jan W
FluidDA, Groeningenlei 132, 2550 Kontich, Belgium. [email protected]
Vos Wim G
Vinchurkar Samir C
Claes Rita
Drollmann Anton
Wulfrank Denis
Parizel Paul M
Germonpré Paul
De Backer Wilfried
Article Info
Journal
Radiology
Abbr.
Radiology
ISSN
1527-1315
Corresponding email
Published
2010-12-00
页码
854-62
Language
English
Country/Region
United States
NLM ID
0401260
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]