Home LiteratureArticle Details
PMID: 21371304 Published · epublish English Journal Article Research Support, Non-U.S. Gov't

Accumulation and transport of microbial-size particles in a pressure protected model burn unit: CFD simulations and experimental evidence.

BMC infectious diseases ·Vol. 11 ·2011-03-03 ·页码 58

Beauchêne C, Laudinet N, Choukri F, Rousset JL, Benhamadouche S, Larbre J, Chaouat M, Benbunan M, Mimoun M, Lajonchère JP, Bergeron V, Derouin F

Abstract

Controlling airborne contamination is of major importance in burn units because of the high susceptibility of burned patients to infections and the unique environmental conditions that can accentuate the infection risk. In particular the required elevated temperatures in the patient room can create thermal convection flows which can transport airborne contaminates throughout the unit. In order to estimate this risk and optimize the design of an intensive care room intended to host severely burned patients, we have relied on a computational fluid dynamic methodology (CFD). The study was carried out in 4 steps: i) patient room design, ii) CFD simulations of patient room design to model air flows throughout the patient room, adjacent anterooms and the corridor, iii) construction of a prototype room and subsequent experimental studies to characterize its performance iv) qualitative comparison of the tendencies between CFD prediction and experimental results. The Electricité De France (EDF) open-source software Code_Saturne® (http://www.code-saturne.org) was used and CFD simulations were conducted with an hexahedral mesh containing about 300 000 computational cells. The computational domain included the treatment room and two anterooms including equipment, staff and patient. Experiments with inert aerosol particles followed by time-resolved particle counting were conducted in the prototype room for comparison with the CFD observations. We found that thermal convection can create contaminated zones near the ceiling of the room, which can subsequently lead to contaminate transfer in adjacent rooms. Experimental confirmation of these phenomena agreed well with CFD predictions and showed that particles greater than one micron (i.e. bacterial or fungal spore sizes) can be influenced by these thermally induced flows. When the temperature difference between rooms was 7°C, a significant contamination transfer was observed to enter into the positive pressure room when the access door was opened, while 2°C had little effect. Based on these findings the constructed burn unit was outfitted with supplemental air exhaust ducts over the doors to compensate for the thermal convective flows. CFD simulations proved to be a particularly useful tool for the design and optimization of a burn unit treatment room. Our results, which have been confirmed qualitatively by experimental investigation, stressed that airborne transfer of microbial size particles via thermal convection flows are able to bypass the protective overpressure in the patient room, which can represent a potential risk of cross contamination between rooms in protected environments.

MeSH 主题词
Air Microbiology Air Pressure Biomedical Engineering/methods Burn Units Computer Simulation France Humans Particulate Matter/analysis Risk Assessment
化学物质
Particulate Matter
作者与单位
共 12 位作者,点击展开单位 / ORCID
Beauchêne Christian
Laboratory of Parasitology-Mycology, Saint-Louis hospital, Assistance Publique-Hôpitaux de Paris, and University Paris, Diderot, France.
Laudinet Nicolas
Choukri Firas
Rousset Jean-Luc
Benhamadouche Sofiane
Larbre Juliette
Chaouat Marc
Benbunan Marc
Mimoun Maurice
Lajonchère Jean-Patrick
Bergeron Vance
Derouin Francis
Article Info
Journal
BMC infectious diseases
Abbr.
BMC Infect Dis
ISSN
1471-2334
Published
2011-03-03
电子出版
2011-00-03
页码
58
Language
English
Country/Region
England
NLM ID
100968551
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]