Very quick reverse transcription polymerase chain reaction for detecting 2009 H1N1 influenza A using wire-guide droplet manipulationst.

Faraday discussions ·Vol. 149 ·2011-00-00 ·页码 159-70; discussion 227-45

You DJ, Tran PL, Kwon HJ, Patel D, Yoon JY

Abstract

Reverse transcription polymerase chain reaction (RT-PCR) is currently a gold standard in identifying influenza A virus, especially H1N1 flu. Typical RT-PCR assays take about 1-2 h for thermocycling, and there is a growing need to further speed up the thermocycling to less than 30 min. Additionally, the PCR assay system should be made portable as a point-of-care detection tool. There have been attempts to further speed up the PCR assays by reducing its volume. There have also been attempts to use droplet microfluidics technology to PCR, primarily to automate the PCR enrichment processes and take advantage of its small volume. In all these attempts, heating and cooling is made by conduction heat transfer. Rapid movements of droplets (immersed in oil) over three different temperature zones make very quick PCR possible, as heating/cooling will be made by convection heat transfer, whose heat transfer coefficients are much higher than that of conduction. We used our newly-invented method of wire-guide droplet manipulations towards very quick RT-PCR. Computational fluid dynamics (CFD) simulation of our system revealed that heating/cooling for each temperature change takes 1-4 s for a 10 microL droplet, as compared to >30 s in the other quick PCRs. Theoretically a 30-cycle process can take as short as 13 s x 30 cycles = 6 min 30 s. The entire system was made as a single instrument, with the components made by a milling machine and a rapid prototyping device. No additional equipment and external computers are required. With this newly developed system, 160 bp gene sequence was amplified from 2009 H1N1 influenza A (human origin). The 30-cycle process took as short as 6 min 50 s for a 10 microL droplet (with additional 4 min for reverse transcription). Its product was confirmed by traditional gel electrophoresis, subsequent imaging as well as gene sequencing, which has been very difficult with the other stationary droplet/nanodrop approaches. The proposed system has a potential to become an extremely rapid, portable, point-of-care tool for detecting influenza A.

MeSH 主题词
Computer Simulation Humans Hydrodynamics Influenza A Virus, H1N1 Subtype/genetics,isolation & purification Influenza, Human/virology RNA, Viral/analysis Reverse Transcriptase Polymerase Chain Reaction/instrumentation,methods
化学物质
RNA, Viral
作者与单位
共 5 位作者,点击展开单位 / ORCID
You David J
Department of Agricultural and Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721-0038, United States .
Tran Phat L
Kwon Hyuck-Jin
Patel Deepa
Yoon Jeong-Yeol
Article Info
Journal
Faraday discussions
Abbr.
Faraday Discuss
ISSN
1359-6640
Published
2011-00-00
页码
159-70; discussion 227-45
Language
English
Country/Region
England
NLM ID
9212301
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]