Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modeling.

Medical engineering & physics ·Vol. 33 ·No. 10 ·2011-12-00 ·页码 1193-202

Giridharan GA, Lederer C, Berthe A, Goubergrits L, Hutzenlaub J, Slaughter MS, Dowling RD, Spence PA, Koenig SC

Abstract

Historically, single port valveless pneumatic blood pumps have had a high incidence of thrombus formation due to areas of blood stagnation and hemolysis due to areas of high shear stress. To ensure minimal hemolysis and favorable blood washing characteristics, particle image velocimetry (PIV) and computational fluid dynamics (CFD) were used to evaluate the design of a new single port, valveless counterpulsation device (Symphony). The Symphony design was tested in 6-h acute (n=8), 5-day (n=8) and 30-day (n=2) chronic experiments in a calf model (Jersey, 76 kg). Venous blood samples were collected during acute (hourly) and chronic (weekly) time courses to analyze for temporal changes in biochemical markers and quantify plasma free hemoglobin. At the end of the study, animals were euthanized and the Symphony and end-organs (brain, liver, kidney, lungs, heart, and spleen) were examined for thrombus formations. Both the PIV and the CFD showed the development of a strong moving vortex during filling phase and that blood exited the Symphony uniformly from all areas during ejection phase. The laminar shear stresses estimated by CFD remained well below the hemolysis threshold of 400 Pa inside the Symphony throughout filling and ejection phases. No areas of persistent blood stagnation or flow separation were observed. The maximum plasma free hemoglobin (<10mg/dl), average platelet count (pre-implant = 473 ± 56 K/μl and post-implant = 331 ± 62 K/μl), and average hematocrit (pre-implant = 31 ± 2% and post-implant = 29 ± 2%) were normal at all measured time-points for each test animal in acute and chronic experiments. There were no changes in measures of hepatic function (ALP, ALT) or renal function (creatinine) from pre-Symphony implantation values. The necropsy examination showed no signs of thrombus formation in the Symphony or end organs. These data suggest that the designed Symphony has good washing characteristics without persistent areas of blood stagnation sites during the entire pump cycle, and has a low risk of hemolysis and thrombus formations.

MeSH 主题词
Animals Artificial Organs Cattle Computer Simulation Counterpulsation/adverse effects,instrumentation Hemolysis Hydrodynamics Male Materials Testing Reproducibility of Results Rheology Stress, Mechanical Thrombosis/etiology Time Factors
作者与单位
共 9 位作者,点击展开单位 / ORCID
Giridharan G A
Departments of Bioengineering & Surgery, Cardiovascular Innovation Institute, University of Louisville, Louisville, KY 40202, USA. [email protected]
Lederer C
Berthe A
Goubergrits L
Hutzenlaub J
Slaughter M S
Dowling R D
Spence P A
Koenig S C
Article Info
Journal
Medical engineering & physics
Abbr.
Med Eng Phys
ISSN
1873-4030
Corresponding email
Published
2011-12-00
电子出版
2011-00-15
页码
1193-202
Language
English
Country/Region
England
NLM ID
9422753
基金资助
NHLBI NIH HHS · R44 HL083586 · United States
NHLBI NIH HHS · R44HL083586-02 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]