Home LiteratureArticle Details
PMID: 22704929 Published · ppublish English Journal Article

Importance of flow stratification and bubble aggregation in the separation zone of a dissolved air flotation tank.

Water research ·Vol. 46 ·No. 14 ·2012-09-15 ·页码 4468-76

Lakghomi B, Lawryshyn Y, Hofmann R

Abstract

The importance of horizontal flow patterns and bubble aggregation on the ability of dissolved air flotation (DAF) systems to improve bubble removal during drinking water treatment were explored using computational fluid dynamics (CFD) modeling. Both analytical and CFD analyses demonstrated benefits to horizontal flow. Two dimensional CFD modeling of a DAF system showed that increasing the amount of air in the system improved the bubble removal and generated a beneficial stratified horizontal flow pattern. Loading rates beyond a critical level disrupted the horizontal flow pattern, leading to significantly lower bubble removal. The results also demonstrated that including the effects of bubble aggregation in CFD modeling of DAF systems is an essential component toward achieving realistic modeling results.

MeSH 主题词
Air Flocculation Hydrodynamics Models, Chemical Rheology/methods Solubility Water Purification/instrumentation,methods
作者与单位
共 3 位作者,点击展开单位 / ORCID
Lakghomi B
Department of Civil Engineering, University of Toronto, 35 St. George Street, Toronto, ON M5S 1A4, Canada. [email protected]
Lawryshyn Y
Hofmann R
Article Info
Journal
Water research
Abbr.
Water Res
ISSN
1879-2448
Corresponding email
Published
2012-09-15
电子出版
2012-00-31
页码
4468-76
Language
English
Country/Region
England
NLM ID
0105072
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]