The purpose of the current study is to evaluate the inactivation of three different kinds of bacteria usually present in municipal wastewater treatment effluents (Enterococcus faecalis, Pseudomonas aeruginosa and Escherichia coli) using a coagulation-flocculation-decantation (CFD) process combined with photo-Fenton treatment at pH 5. Different concentrations of Fe(3+)-H2O2 (0.4/25, 5/25 and 15/25 mg L(-1)), and H2O2 (25 mg L(-1)) were evaluated for 210 minutes under artificial solar irradiation in a solar chamber ATLAS SUNTEST CPS+. The results were compared applying the CFD process before or after the disinfection treatment. The results of the bacteria inactivation show that the highest rate was observed using CFD-photo-Fenton treatment with 15 mg L(-1) of Fe(3+) and 25 mg L(-1) of H2O2, obtaining the total inactivation of Pseudomonas sp., a 5.64-log inactivation of Enterococcus sp. and a 4.61-log inactivation of E. coli. In addition, turbidity and suspended solids decreased more than 90% with the combined treatments. The treated wastewater samples could be reused in urban, agricultural, industrial, recreational and environmental uses according to current Spanish legislation (RD 1620/2007).
No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong
Qilu Normal University · Genelibs Bioinformatics Lab
750 Shunhua Rd, Jinan
2F, Bldg F, University Science Park
Tel: 0531-88819269
Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.
Business Email
E-mail: [email protected]