Home LiteratureArticle Details
PMID: 23889366 Published · ppublish English Comparative Study Journal Article

Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images.

Artificial organs ·Vol. 38 ·No. 2 ·2014-02-00 ·页码 142-8

Karmonik C, Partovi S, Schmack B, Weymann A, Loebe M, Noon GP, Piontek P, Karck M, Lumsden AB, Ruhparwar A

Abstract

This study aims to investigate differences in hemodynamic conditions in the thoracic aorta for pulsatile and continuous-flow left ventricular assist devices (LVADs) using computational fluid dynamics (CFD). Patient-specific models were reconstructed from three patients with continuous-flow LVAD (HeartMate II, Thoratec Corporation) and three patients with biventricular assist devices (Excor, Berlin Heart) where only the aortic part was included in the simulations. CFD simulations were performed with constant inflow for the continuous-flow LVADs and time-varying inflow for the pulsatile devices. Differences in flow patterns, wall shear stress (WSS), and dynamic pressure in the ascending aorta were compared for both cases. Retrograde flow patterns were observed in all cases proximal to the location of the outflow cannula anastomosis site. On average, dynamic pressures derived from the retrograde flow velocities were higher in the continuous-flow group with large variations dependent on the angle of the cannula anastomosis relative to the ascending aorta (continuous group: 0.14 ± 0.2 mm Hg, pulsatile group: 0.013 ± 0.008 mm Hg). Elevated WSS contralaterally to the anastomosis site was observed in three of the six models with higher values for the continuous cases. Lower WSS and reduced pressure in the ascending aorta, both favorable hemodynamic conditions, were found in pulsatile versus continuous-flow LVADs by means of CFD. These findings indicate, along with clinical observations reported by others, the superior performance of pulsatile LVADs.

Keywords
Computational fluid dynamics Continuous flow Hemodynamics Left ventricular assist device Pulsatile flow
MeSH 主题词
Aorta/physiology Aortography Heart-Assist Devices Hemodynamics/physiology Humans Hydrodynamics Models, Cardiovascular
作者与单位
共 10 位作者,点击展开单位 / ORCID
Karmonik Christof
Department of Neurosurgery, The Methodist Hospital, Houston, TX, USA; Methodist DeBakey Heart & Vascular Center, The Methodist Hospital, Houston, TX, USA.
Partovi Sasan
Schmack Bastian
Weymann Alexander
Loebe Matthias
Noon George P
Piontek Patrizia
Karck Matthias
Lumsden Alan B
Ruhparwar Arjang
Article Info
Journal
Artificial organs
Abbr.
Artif Organs
ISSN
1525-1594
Published
2014-02-00
电子出版
2013-00-25
页码
142-8
Language
English
Country/Region
United States
NLM ID
7802778
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]