Home LiteratureArticle Details
PMID: 24265876 Published · ppublish English Journal Article

Experimental validation of numerical simulations on a cerebral aneurysm phantom model.

Interventional medicine & applied science ·Vol. 4 ·No. 4 ·2012-12-00 ·页码 193-205

Bordás R, Seshadhri S, Janiga G, Skalej M, Thévenin D

Abstract

The treatment of cerebral aneurysms, found in roughly 5% of the population and associated in case of rupture to a high mortality rate, is a major challenge for neurosurgery and neuroradiology due to the complexity of the intervention and to the resulting, high hazard ratio. Improvements are possible but require a better understanding of the associated, unsteady blood flow patterns in complex 3D geometries. It would be very useful to carry out such studies using suitable numerical models, if it is proven that they reproduce accurately enough the real conditions. This validation step is classically based on comparisons with measured data. Since in vivo measurements are extremely difficult and therefore of limited accuracy, complementary model-based investigations considering realistic configurations are essential. In the present study, simulations based on computational fluid dynamics (CFD) have been compared with in situ, laser-Doppler velocimetry (LDV) measurements in the phantom model of a cerebral aneurysm. The employed 1:1 model is made from transparent silicone. A liquid mixture composed of water, glycerin, xanthan gum and sodium chloride has been specifically adapted for the present investigation. It shows physical flow properties similar to real blood and leads to a refraction index perfectly matched to that of the silicone model, allowing accurate optical measurements of the flow velocity. For both experiments and simulations, complex pulsatile flow waveforms and flow rates were accounted for. This finally allows a direct, quantitative comparison between measurements and simulations. In this manner, the accuracy of the employed computational model can be checked.

Keywords
blood-analog fluid cerebral aneurysm computational fluid dynamics (CFD) laser-Doppler velocimetry (LDV) phantom model
作者与单位
共 5 位作者,点击展开单位 / ORCID
Bordás Róbert
Seshadhri Santhosh
Janiga Gábor
Skalej Martin
Thévenin Dominique
Article Info
Journal
Interventional medicine & applied science
Abbr.
Interv Med Appl Sci
ISSN
2061-1617
Published
2012-12-00
电子出版
2012-00-27
页码
193-205
Language
English
Country/Region
Hungary
NLM ID
101539233
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]