Home LiteratureArticle Details
PMID: 24307634 Published · ppublish English

The real world experience of the biodegradable polymer-coated sirolimus-eluting coronary stent system: Results From an "All-Comers" Clinical Experience.

Rajasekhar D, Vanajakshamma V, Shashank C, Srinivasakumar M L, Sivasankara C

Abstract

This INDOLIMUS Registry sought to evaluate the safety and efficacy of the biodegradable polymer coated Indolimus(®) sirolimus-eluting coronary stent for the treatment of coronary artery disease across a wide range of patients treated in routine clinical practice, including those with high-risk characteristics and complex lesions.,First-generation drug-eluting stents utilize nonbiodegradable polymeric coatings, whose persistent presence in the arterial wall may negatively affect long-term outcomes. It has been hypothesized that persistent presence of polymer may compromise the safety of drug-eluting stents, and that therefore biodegradable polymer coatings might reduce late adverse events in an unselected patient population.,All 530 consecutive unselected patients (415 males and 115 females) included who underwent percutaneous coronary intervention at the Sri Venkateswara Institute of Medical Sciences, Tirupati, India between August 2012 and March 2013, with an in-hospital, at 30-days and at 6-months follow-up. Retrospective analysis of those data had been done.,A total of 617 lesions were treated in 530 enrolled patients (mean age 54.9 ± 10.8 years) with average stent length of 18.8 ± 6.0 mm. An average of 1.18 stents was implanted per patient. The patients' characteristics are noted as having 169 (31.9%) patients of diabetics and 215 (40.6%) hypertension. Smoking, alcoholism and tobacco chewing were found in 273 (51.5%), 130 (24.5%) and 17 (3.2%), respectively. The indications for intervention were unstable angina in 77 (14.5%) and previous myocardial infarction in 56 (10.6%) of the patients. Lesions were of type B2 in 264 (42.7%) and type C in 127 (20.6%). Stent delivery was successful in all cases and in-hospital, 30-days and 6-months follow-up of all 530 patients was obtained. The incidence of any major adverse cardiac events at in-hospital, at 30-days and at 6-months were 5 (0.94%), 8 (1.52%), and 18 (3.40%), respectively. Long term follow-up of this registry is ongoing to confirm safety and efficacy profiles.,The relatively low event rate that was observed in INDOLIMUS Registry indicates that the biodegradable polymer coated Indolimus(®) sirolimus-eluting coronary stent can achieve excellent clinical performances in a large group of patients. © 2013 Wiley Periodicals, Inc.

Keywords
coronary artery disease percutaneous coronary intervention thrombosis
Article Info
Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Abbr.
Catheter Cardiovasc Interv
Published
0000-00-00
Indexed
2016-09-13
Updated
2016-09-13
Language
English
Country/Region
United States
NLM ID
100884139
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]