Home LiteratureArticle Details
PMID: 24533575 Published · ppublish English Journal Article

Development of a hemodynamically optimized outflow cannula for cardiopulmonary bypass.

Artificial organs ·Vol. 38 ·No. 11 ·2014-11-00 ·页码 972-8

Kaufmann TA, Schlanstein P, Moritz A, Steinseifer U

Abstract

The jet of the outflow cannula is a potential risk for patients undergoing cardiopulmonary bypass (CPB), because increased jet velocities lead to altered flow conditions and might furthermore mobilize atherosclerotic plaques from calcified aortas. The cannula jet is therefore among the main reasons for cerebral hypoxia and stroke in CPB patients. In the past, we developed a validated computational fluid dynamics (CFD) model to analyze flow conditions during CPB as dependent on cannulation and support modalities. This model is now applied to develop a novel CPB outflow cannula to reduce the jet effect and increase cerebral blood flow. The Multi-Module Cannula (MMC) is based on a generic elbow cannula that was iteratively improved. It features an inner wall to smoothly guide the blood as well as an elliptically shaped outlet diffuser. During standard CPB conditions of 5 L/min, the pressure drop over the MMC is 61 mm Hg, compared with 68 mm Hg with a standard cannula. The maximum velocities are decreased from 3.7 m/s to 3.3 m/s. In the cannula jet of the MMC, the velocities are reduced further, down to 1.6 m/s. The cerebral blood flow is typically reduced during CPB. Using the MMC, however, it reaches almost physiological values at 715 mL/min. These results suggest that the MMC outperforms standard CPB cannulas. Further design improvements and improved insertion techniques are under consideration.

Keywords
Cannula design Cannulation Cardiopulmonary bypass Computational fluid dynamics
MeSH 主题词
Blood Flow Velocity/physiology Cardiopulmonary Bypass/instrumentation Cerebrovascular Circulation/physiology Equipment Design Hemodynamics Humans Hydrodynamics Models, Cardiovascular
作者与单位
共 4 位作者,点击展开单位 / ORCID
Kaufmann Tim A S
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Aachen, Germany.
Schlanstein Peter
Moritz Anton
Steinseifer Ulrich
Article Info
Journal
Artificial organs
Abbr.
Artif Organs
ISSN
1525-1594
Published
2014-11-00
电子出版
2014-00-17
页码
972-8
Language
English
Country/Region
United States
NLM ID
7802778
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]