Home LiteratureArticle Details
PMID: 24721753 Published · ppublish English Comparative Study Journal Article

Quantitative comparison of hemodynamic parameters from steady and transient CFD simulations in cerebral aneurysms with focus on the aneurysm ostium.

Journal of neurointerventional surgery ·Vol. 7 ·No. 5 ·2015-05-00 ·页码 367-72

Karmonik C, Diaz O, Klucznik R, Grossman RG, Zhang YJ, Britz G, Lv N, Huang Q

Abstract

To quantitatively compare hemodynamics simulated with steady-state and transient computational fluid dynamics (CFD) simulations in cerebral aneurysms with single inflow, with focus at the aneurysm ostium. Transient and steady-state CFD simulations were performed in 10 cerebral aneurysms. Distributions and average values for pressure, helicity, vorticity, and velocity were qualitatively compared at proximal and distal parent artery locations, at the ostium plane, and in the aneurysm, and scaling factors between the two kinds of simulations were determined. Relative inflow and outflow areas at the ostium were compared, as were average inflow and outflow velocities. In addition, values for the pressure-loss coefficient (PLC), a recently introduced parameter to assess aneurysm rupture risk, were compared for both kinds of simulation. Distributions of hemodynamic parameters had a similar shape but were lower for transient than for steady-state simulations. Averaged scaling factors over cases and anatomical locations showed differences for hemodynamic parameters (0.485 ± 0.01 for pressure, 0.33 ± 0.02 for helicity, 0.58 ± 0.06 for vorticity and 0.56 ± 0.04 for velocity). Good agreement between ratios of inflow and outflow areas at the aneurysm ostium was obtained (Pearson correlation coefficient >0.97, p<0.001) and for the PLC (linear regression slope 0.73 ± 0.14, R(2)=0.75). Steady-state simulations are a quick alternative to transient simulation for visualizing and quantifying inflow and outflow areas at the aneurysm ostium, potentially of value when planning flow diverter treatment and for quantifying the PLC, a potential indicator of aneurysm rupture.

Keywords
Aneurysm Blood Flow
MeSH 主题词
Computer Simulation Hemodynamics/physiology Humans Hydrodynamics Intracranial Aneurysm/physiopathology Models, Cardiovascular
作者与单位
共 8 位作者,点击展开单位 / ORCID
Karmonik C
Department of Neurosurgery, Houston Methodist, Houston, Texas, USA.
Diaz O
Department of Radiology, Houston Methodist, Houston, Texas, USA.
Klucznik R
Department of Radiology, Houston Methodist, Houston, Texas, USA.
Grossman R G
Department of Neurosurgery, Houston Methodist, Houston, Texas, USA.
Zhang Y J
Department of Neurosurgery, Houston Methodist, Houston, Texas, USA.
Britz G
Department of Neurosurgery, Houston Methodist, Houston, Texas, USA.
Lv N
Department of Neurosurgery, the Affiliated Changhai Hospital of Second Military Medical University, Shanghai, China.
Huang Q
Department of Neurosurgery, the Affiliated Changhai Hospital of Second Military Medical University, Shanghai, China.
Article Info
Journal
Journal of neurointerventional surgery
Abbr.
J Neurointerv Surg
ISSN
1759-8486
Published
2015-05-00
电子出版
2014-00-10
页码
367-72
Language
English
Country/Region
England
NLM ID
101517079
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]