Accuracy of diffusion-weighted (DW) MRI with background signal suppression (MR-DWIBS) in diagnosis of mediastinal lymph node metastasis of nonsmall-cell lung cancer (NSCLC).

Journal of magnetic resonance imaging : JMRI ·第 40 卷 ·第 1 期 ·2015-02-05

Xu Liang, Tian Jiakai, Liu Yuhui, Li Chuanfu

摘要

To prospectively evaluate the accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging with background signal suppression (MR-DWIBS) for detecting mediastinal lymph node metastasis of nonsmall-cell lung cancer (NSCLC).,MR-DWIBS was performed in 42 consecutive patients (27 men, 15 women; age range, 42-78 years; median age, 55 years) with histologically proven NSCLC. The visualization rate of metastatic lymph node (MLN) and benign lymph node (BLN) of enlarged lymph nodes (ELN) and normal-sized lymph nodes (NLN) was compared by using a chi-square test or Fisher's exact test on a per-nodal basis. Apparent diffusion coefficient (ADC) of MLN and BLN was measured and compared by using two-tailed unpaired Student's t-test. Receiver operating characteristic (ROC) analysis was used to assess the overall diagnostic accuracy of ADC for ELN and NLN. The optimal cutoff value was determined and the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy was calculated.,Thirty-five out of 119 lymph resected nodes were confirmed to be metastatic by histologic examination. The visualization rate of MLN was significantly higher than that of BLN for ELN (P < 0.001) and for NLN (χ(2) = 7.506, P = 0.006). For both ELN and NLN, ADC of MLN was significantly lower than that of BLN (t = -5.380, P < 0.001 and t = -6.435, P < 0.001). ADC was significant for detection of MLN for both ELN (Az = 0.975, P < 0.001) and NLN (Az = 0.919, P < 0.001). For NLN, the optimal cutoff value of ADC was 2.04 mm(2)/s, where the sensitivity, specificity, PPV, NPV, and accuracy were 75.0%, 90.9%, 66.7%, 93.8%, and 87.8%, respectively.,MR-DWIBS may be clinically useful to visually detect mediastinal lymph nodes and ADC measurement can aid in malignant node discrimination.

关键词
diffusion magnetic resonance imaging lung neoplasms lymphatic metastasis magnetic resonance imaging neoplasm metastasis
文献信息
期刊
Journal of magnetic resonance imaging : JMRI
期刊简称
J Magn Reson Imaging
发表日期
2015-02-05
收录日期
2014-06-13
更新日期
2014-06-13
语言
英语
国家/地区
United States
NLM ID
9105850
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]