Home LiteratureArticle Details
PMID: 25006349 Published · epublish English Journal Article

Does a mobile laminar airflow screen reduce bacterial contamination in the operating room? A numerical study using computational fluid dynamics technique.

Patient safety in surgery ·Vol. 8 ·2014-00-00 ·页码 27

Sadrizadeh S, Tammelin A, Nielsen PV, Holmberg S

Abstract

Air-borne bacteria in the operating room (OR) may contaminate the surgical wound, either by direct sedimentation from the air or indirectly, by contaminated sterile instruments. Reduced air contamination can be achieved with an efficient ventilation system. The current study assesses the additive effect of a mobile laminar airflow (MLAF) unit on the microbiological air quality in an OR supplied with turbulent-mixing air ventilation. A recently designed OR in NKS (Nya Karolinska Sjukhuset, Stockholm, Sweden) was the physical model for this study. Simulation was made with MLAF units adjacent to the operating table and the instrument tables, in addition to conventional turbulent-mixing ventilation. The evaluation used numerical calculation by computational fluid dynamics (CFD). Sedimentation rates (CFU/m(2)/h) were calculated above the operating table and two instrument tables, and in the periphery of the OR. Bacterial air contamination (CFU/m(3)) was simulated above the surgical and instrument tables with and without the MLAF unit. The counts of airborne and sedimenting, bacteria-carrying particles downstream of the surgical team were reduced to an acceptable level for orthopedic/implant surgery when the MLAF units were added to conventional OR ventilation. No significant differences in mean sedimentation rates were found in the periphery of the OR. The MLAF screen unit can be a suitable option when the main OR ventilation system is unable to reduce the level of microbial contamination to an acceptable level for orthopedic implant surgery. However, MLAF effect is limited to an area within 1 m from the screen. Increasing air velocity from the MLAF above 0.4 m/s does not increase the impact area.

Keywords
Air-borne bacteria CFD simulation Colony-forming unit Microbiological air quality Mobile ultraclean exponential laminar airflow screen Operating room
作者与单位
共 4 位作者,点击展开单位 / ORCID
Sadrizadeh Sasan
Division of Fluid and Climate Technology, School of Architecture and the Built Environment, KTH Royal Institute of Technology, Stockholm, Sweden.
Tammelin Ann
Department of Medicine, Solna (MedS), Unit of Infectious Diseases, Karolinska Institutet, Stockholm, Sweden.
Nielsen Peter V
Department of Civil Engineering, Aalborg University, Aalborg, Denmark.
Holmberg Sture
Division of Fluid and Climate Technology, School of Architecture and the Built Environment, KTH Royal Institute of Technology, Stockholm, Sweden.
Article Info
Journal
Patient safety in surgery
Abbr.
Patient Saf Surg
ISSN
1754-9493
Published
2014-00-00
电子出版
2014-00-26
页码
27
Language
English
Country/Region
England
NLM ID
101319176
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]