Home LiteratureArticle Details
PMID: 25798761 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Hemodynamic transition driven by stent porosity in sidewall aneurysms.

Journal of biomechanics ·Vol. 48 ·No. 7 ·2015-05-01 ·页码 1300-9

Bouillot P, Brina O, Ouared R, Lovblad KO, Farhat M, Pereira VM

Abstract

The healing process of intracranial aneurysms (IAs) treated with flow diverter stents (FDSs) depends on the IA flow modifications and on the epithelization process over the neck. In sidewall IA models with straight parent artery, two main hemodynamic regimes with different flow patterns and IA flow magnitude were broadly observed for unstented and high porosity stented IA on one side, and low porosity stented IA on the other side. The hemodynamic transition between these two regimes is potentially involved in thrombosis formation. In the present study, CFD simulations and multi-time lag (MTL) particle imaging velocimetry (PIV) measurements were combined to investigate the physical nature of this transition. Measurable velocity fields and non-measurable shear stress and pressure fields were assessed experimentally and numerically in the aneurysm volume in the presence of stents with various porosities. The two main regimes observed in both PIV and CFD showed typical flow features of shear and pressure driven regimes. In particular, the waveform of the averaged IA velocities was matching both the shear stress waveform at IA neck or the pressure gradient waveform in parent artery. Moreover, the transition between the two regimes was controlled by stent porosity: a decrease of stent porosity leads to an increase (decrease) of pressure differential (shear stress) through IA neck. Finally, a good PIV-CFD agreement was found except in transitional regimes and low motion eddies due to small mismatch of PIV-CFD running conditions.

Keywords
Cerebral aneurysm Computational fluid dynamics Hemodynamic transition Hemodynamics Particle imaging velocimetry Stent
MeSH 主题词
Computer Simulation Hemodynamics Humans Hydrodynamics Intracranial Aneurysm/therapy Porosity Pressure Rheology Shear Strength Stents Stress, Mechanical
作者与单位
共 6 位作者,点击展开单位 / ORCID
Bouillot Pierre
Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospital of Geneva, Switzerland; Laboratory for Hydraulic Machines (LMH), École Polytechnique Fédérale de Lausanne (EPFL), Avenue de Cour 33bis, CH-1007 Lausanne, Switzerland. Electronic address: [email protected].
Brina Olivier
Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospital of Geneva, Switzerland.
Ouared Rafik
Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospital of Geneva, Switzerland.
Lovblad Karl-Olof
Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospital of Geneva, Switzerland.
Farhat Mohamed
Laboratory for Hydraulic Machines (LMH), École Polytechnique Fédérale de Lausanne (EPFL), Avenue de Cour 33bis, CH-1007 Lausanne, Switzerland.
Pereira Vitor Mendes
Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospital of Geneva, Switzerland; Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, ON, Canada; Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, Toronto, ON, Canada.
Article Info
Journal
Journal of biomechanics
Abbr.
J Biomech
ISSN
1873-2380
Corresponding email
Published
2015-05-01
电子出版
2015-00-26
页码
1300-9
Language
English
Country/Region
United States
NLM ID
0157375
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]