Home LiteratureArticle Details
PMID: 25869720 Published · ppublish English Comparative Study Journal Article Research Support, Non-U.S. Gov't

Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

Journal of biomechanics ·Vol. 48 ·No. 10 ·2015-07-16 ·页码 2090-5

Meirson T, Orion E, Avrahami I

Abstract

This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses patients׳ specific computational fluid dynamics (CFD) methods to characterize the relevant hemodynamic parameters of patients׳ SVGs. The method was used to compare the hemodynamics of six patient׳s specific model and flow conditions of stented and non-stented SVGs, 12 months post-transplantation. The flow parameters used to characterize the grafts׳ hemodynamics include Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI) and Relative Residence Time (RRT). The effect of stenting was clearly demonstrated by the chosen parameters. SVGs under constriction of VEST were associated with similar spatial average of TAWSS (10.73 vs 10.29 dyn/cm(2)), yet had fewer lesions with low TAWSS, lower OSI (0.041 vs 0.08) and RRT (0.12 vs 0.24), and more uniform flow with less flow discrepancies. In conclusion, the suggested method and parameters well demonstrated the advantage of VEST support. Stenting vein grafts with VEST improved hemodynamic factors which are correlated to graft failure following CABG procedure.

Keywords
CABG CFD Hemodynamics Saphenous vein VEST
MeSH 主题词
Coronary Artery Bypass/methods Hemodynamics/physiology Humans Hydrodynamics Models, Theoretical Saphenous Vein/physiology,transplantation Stents Stress, Mechanical Tissue Scaffolds
作者与单位
共 3 位作者,点击展开单位 / ORCID
Meirson T
Department of Medical Engineering, Afeka Academic College of Engineering, Tel Aviv, Israel. Electronic address: [email protected].
Orion E
Vascular Graft Solutions Ltd., Tel Aviv 6971921, Israel.
Avrahami I
Department of Mechanical Engineering & Mechatronics, Ariel University, Israel.
Article Info
Journal
Journal of biomechanics
Abbr.
J Biomech
ISSN
1873-2380
Corresponding email
Published
2015-07-16
电子出版
2015-00-19
页码
2090-5
Language
English
Country/Region
United States
NLM ID
0157375
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]