Home LiteratureArticle Details
PMID: 26473395 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

The Computational Fluid Dynamics Rupture Challenge 2013--Phase II: Variability of Hemodynamic Simulations in Two Intracranial Aneurysms.

Journal of biomechanical engineering ·Vol. 137 ·No. 12 ·2015-12-00 ·页码 121008

Berg P, Roloff C, Beuing O, Voss S, Sugiyama S, Aristokleous N, Anayiotos AS, Ashton N, Revell A, Bressloff NW, Brown AG, Chung BJ, Cebral JR, Copelli G, Fu W, Qiao A, Geers AJ, Hodis S, Dragomir-Daescu D, Nordahl E, Bora Suzen Y, Owais Khan M, Valen-Sendstad K, Kono K, Menon PG, Albal PG, Mierka O, Münster R, Morales HG, Bonnefous O, Osman J, Goubergrits L, Pallares J, Cito S, Passalacqua A, Piskin S, Pekkan K, Ramalho S, Marques N, Sanchi S, Schumacher KR, Sturgeon J, Švihlová H, Hron J, Usera G, Mendina M, Xiang J, Meng H, Steinman DA, Janiga G

Abstract

With the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not prescribed. In order to compare the computational results of one representative group with experimental results, steady-flow measurements using particle image velocimetry (PIV) were carried out in a silicone model of one of the provided aneurysms. Approximately 80% of the participating groups generated similar results. Both velocity and pressure computations were in good agreement with each other for cycle-averaged and peak-systolic predictions. Most apparent "outliers" (results that stand out of the collective) were observed to have underestimated velocity levels compared to the majority of solutions, but nevertheless identified comparable flow structures. In only two cases, the results deviate by over 35% from the mean solution of all the participants. Results of steady CFD simulations of the representative group and PIV experiments were in good agreement. The study demonstrated that while a range of numerical schemes, mesh resolution, and solvers was used, similar flow predictions were observed in the majority of cases. To further validate the computational results, it is suggested that time-dependent measurements should be conducted in the future. However, it is recognized that this study does not include the biological aspects of the aneurysm, which needs to be considered to be able to more precisely identify the specific rupture risk of an intracranial aneurysm.

MeSH 主题词
Aneurysm, Ruptured/physiopathology Blood Flow Velocity Blood Pressure Cerebrovascular Circulation Computer Simulation Humans Intracranial Aneurysm/physiopathology Models, Cardiovascular Shear Strength
作者与单位
共 50 位作者,点击展开单位 / ORCID
Berg Philipp
Roloff Christoph
Beuing Oliver
Voss Samuel
Sugiyama Shin-Ichiro
Aristokleous Nicolas
Anayiotos Andreas S
Ashton Neil
Revell Alistair
Bressloff Neil W
Brown Alistair G
Chung Bong Jae
Cebral Juan R
Copelli Gabriele
Fu Wenyu
Qiao Aike
Geers Arjan J
Hodis Simona
Dragomir-Daescu Dan
Nordahl Emily
Bora Suzen Yildirim
Owais Khan Muhammad
Valen-Sendstad Kristian
Kono Kenichi
Menon Prahlad G
Albal Priti G
Mierka Otto
Münster Raphael
Morales Hernán G
Bonnefous Odile
Osman Jan
Goubergrits Leonid
Pallares Jordi
Cito Salvatore
Passalacqua Alberto
Piskin Senol
Pekkan Kerem
Ramalho Susana
Marques Nelson
Sanchi Stéphane
Schumacher Kristopher R
Sturgeon Jess
Švihlová Helena
Hron Jaroslav
Usera Gabriel
Mendina Mariana
Xiang Jianping
Meng Hui
Steinman David A
Janiga Gábor
Article Info
Journal
Journal of biomechanical engineering
Abbr.
J Biomech Eng
ISSN
1528-8951
Published
2015-12-00
页码
121008
Language
English
Country/Region
United States
NLM ID
7909584
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]