Home LiteratureArticle Details
PMID: 26577365 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't Validation Study

Particle Image Velocimetry Used to Qualitatively Validate Computational Fluid Dynamic Simulations in an Oxygenator: A Proof of Concept.

Cardiovascular engineering and technology ·Vol. 6 ·No. 3 ·2015-09-00 ·页码 340-51

Schlanstein PC, Hesselmann F, Jansen SV, Gemsa J, Kaufmann TA, Klaas M, Roggenkamp D, Schröder W, Schmitz-Rode T, Steinseifer U, Arens J

Abstract

Computational fluid dynamics (CFD) is used to simulate blood flow inside the fiber bundles of oxygenators. The results are interpreted in terms of flow distribution, e.g., stagnation and shunt areas. However, experimental measurements that provide such information on the local flow between the fibers are missing. A transparent model of an oxygenator was built to perform particle image velocimetry (PIV), to perform the experimental validation. The similitude theory was used to adjust the size of the PIV model to the minimal resolution of the PIV system used (scale factor 3.3). A standard flow of 80 mL/min was simulated with CFD for the real oxygenator and the equivalent flow of 711 mL/min, according to the similitude theory, was investigated with PIV. CFD predicts the global size of stagnation and shunt areas well, but underestimates the streamline length and changes in velocities due to the meandering flow around the real fibers in the PIV model. Symmetrical CFD simulation cannot consider asymmetries in the flow, due to manufacturing-related asymmetries in the fiber bundle. PIV could be useful for validation of CFD simulations; measurement quality however must be improved for a quantitative validation of CFD results and the investigation of flow effects such as tortuosity and anisotropic flow behavior.

Keywords
Artificial lung Artificial placenta CFD Experimental flow visualization Hollow fiber membrane PIV Porous media
MeSH 主题词
Computer Simulation Equipment Design Hemodynamics Hydrodynamics Models, Cardiovascular Oxygenators, Membrane Rheology/methods
作者与单位
共 11 位作者,点击展开单位 / ORCID
Schlanstein Peter C
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany. [email protected].
Hesselmann Felix
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Jansen Sebastian V
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Gemsa Jeannine
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Kaufmann Tim A
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Klaas Michael
Institute of Aerodynamics, RWTH Aachen University, Wüllnerstr. 5a, 52062, Aachen, Germany.
Roggenkamp Dorothee
Institute of Aerodynamics, RWTH Aachen University, Wüllnerstr. 5a, 52062, Aachen, Germany.
Schröder Wolfgang
Institute of Aerodynamics, RWTH Aachen University, Wüllnerstr. 5a, 52062, Aachen, Germany.
Schmitz-Rode Thomas
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Steinseifer Ulrich
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Arens Jutta
Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
Article Info
Journal
Cardiovascular engineering and technology
Abbr.
Cardiovasc Eng Technol
ISSN
1869-4098
Corresponding email
Published
2015-09-00
电子出版
2015-00-27
页码
340-51
Language
English
Country/Region
United States
NLM ID
101531846
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]