Blood Flow Simulations for the Design of Stented Valve Reducer in Enlarged Ventricular Outflow Tracts.

Cardiovascular engineering and technology ·Vol. 6 ·No. 4 ·2015-12-00 ·页码 485-500

Caiazzo A, Guibert R, Boudjemline Y, Vignon-Clementel IE

Abstract

Tetralogy of Fallot is a congenital heart disease characterized over time, after the initial repair, by the absence of a functioning pulmonary valve, which causes regurgitation, and by progressive enlargement of the right ventricle outflow tract (RVOT). Due to this pathological anatomy, available transcatheter valves are usually too small to be deployed there. To avoid surgical valve replacement, an alternative consists in implanting a reducer prior to or in combination with the valve. It has been shown in animal experiments to be promising, but with some limitations. The effect of a percutaneous pulmonary valve reducer on hemodynamics in enlarged RVOT is thus studied by computational modeling. To this aim, blood flow in the RVOT is modeled with CFD coupled to a simplified valve model and 0D downstream models. Simulations are performed in an image-based geometry and boundary conditions tuned to reproduce the pathological flow without the device. Different device designs are built and compared with the initial device-free state, or with the reducer alone. Results suggest that pressure loss is higher for the reducer alone than for the full device, and that the latter successfully restores hemodynamics to a healthy state and induces a more symmetric flow in the pulmonary arteries. Moreover, pressure forces on the reducer and on the valve have the same magnitudes. Migration would occur towards the right ventricle rather than the pulmonary arteries. Results support the thesis that the reducer does not introduce clinically significant pressure gradients, as was found in animal experiments. Such study could help transfer to patients.

Keywords
Device design Multi scale blood flow simulations Percutaneous pulmonary valve replacement Repaired tetralogy of fallot Right ventricle outflow tract (RVOT)
MeSH 主题词
Algorithms Blood Flow Velocity/physiology Computer Simulation Heart Valve Prosthesis Heart Valve Prosthesis Implantation/adverse effects,instrumentation,methods Hemodynamics/physiology Humans Models, Cardiovascular Patient-Specific Modeling Prosthesis Design Pulmonary Artery/physiopathology Pulmonary Valve/physiopathology,surgery Stents Tetralogy of Fallot/physiopathology,surgery Ventricular Outflow Obstruction/surgery
作者与单位
共 4 位作者,点击展开单位 / ORCID
Caiazzo Alfonso
Weierstrass Institute for Applied Analysis and Stochastics, Mohrenstrasse 39, Berlin, 10117, Germany. [email protected].
Guibert Romain
Institut de Mécanique des Fluides de Toulouse, INPT, UPS, Université de Toulouse, Toulouse, France. [email protected].
Boudjemline Younes
Service de Cardiologie Pédiatrique, Hôpital Necker-Enfants Malades, Paris, France. [email protected].
Vignon-Clementel Irene E
INRIA Paris-Rocquencourt and Sorbonne Universités UPMC Univ. Paris 6, Laboratoire J.-L. Lions, Paris, France. [email protected].
Article Info
Journal
Cardiovascular engineering and technology
Abbr.
Cardiovasc Eng Technol
ISSN
1869-4098
Published
2015-12-00
电子出版
2015-00-07
页码
485-500
Language
English
Country/Region
United States
NLM ID
101531846
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]