主页 文献库文献详情
PMID: 26694940 已发表 · ppublish 英语

Gradient between dorsalis pedis and radial arterial blood pressures during sevoflurane anaesthesia: A self-control study in patients undergoing neurosurgery.

European journal of anaesthesiology ·第 33 卷 ·第 2 期 ·2016-09-26

Chen Yan, Cui Jian, Sun James J, Wang Enqin, Zhu Yuan, Li Yongshuai, Lu Kaizhi

摘要

The dorsalis pedis artery (DPA) is a good alternative to the radial artery (RA) for invasive blood pressure monitoring when the upper limb is burned or injured, or if the RA is not available. Understanding the pattern of pressure difference between DPA and the commonly used RA during inhalational anaesthesia is helpful for haemodynamic management and therapeutic decisions.,The objective of this study was to investigate the time-dependent variation of DPA-to-RA pressure gradient during sevoflurane anaesthesia and the overall difference between the two pressures during neurosurgery, together with the causes of the pressure gradient change.,A prospective, self-control, single-centre study.,The operating room of a teaching hospital from 1 January 2013 to 1 September 2013.,Thirty-seven patients between 18 and 60 years of age, American Society of Anesthesiologists' physical status 1-3, scheduled for neurosurgery in the supine position and requiring invasive arterial pressure monitoring.,The time-dependent change of DPA-to-RA pressure gradient and skin temperature gradient, the difference between absolute values and average values of SBP, DBP and mean blood pressure (MBP) between RA and DPA during surgery, and the internal cross-sections and systolic blood flow velocities of RA and DPA at the baseline and at the end of surgery.,Data from 30 patients were analysed. The mean ± standard deviation DPA-to-RA pressure gradient gradually decreased with time from 9.7 ± 8.8 to -1.8 ± 7.6 mmHg for systolic pressure, -2.3 ± 2.7 to -3.7 ± 2.8 mmHg for diastolic pressure and -2.1 ± 3.2 to -5.4 ± 3.4 mmHg for MBP. Biases during the entire procedure were 2.2 ± 10.1, -3.1 ± 3.4 and -4.3 ± 4.2 mmHg for SBP, DBP and MBP, respectively. The DPA-to-RA skin temperature gradient gradually reduced from -3.6 ± 2.4 to -1.1 ± 1.3°C. A greater increase in the inner cross-sectional area and blood flow from the baseline was observed at DPA compared with RA.,The blood pressure, temperature and inner cross-sectional area differences between DPA and RA reduced gradually during sevoflurane anaesthesia in patients undergoing neurosurgery. Therapeutic decisions may rely on DPA pressure as long as the anaesthetists are aware of the pattern of change in DPA pressure during surgery.,www.chictr.org with registry number ChiCTR-RNRC-13003853.

文献信息
期刊
European journal of anaesthesiology
期刊简称
Eur J Anaesthesiol
发表日期
2016-09-26
收录日期
2015-12-23
更新日期
2016-11-26
语言
英语
国家/地区
England
NLM ID
8411711
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]