Abstract
Computational fluid dynamics (CFD) can have a complementary predictive role alongside the exquisite visualization capabilities of 4D cardiovascular magnetic resonance (CMR) imaging. In order to exploit these capabilities (e.g., for decision-making), it is necessary to validate computational models against real world data. In this study, we sought to acquire 4D CMR flow data in a controllable, experimental setup and use these data to validate a corresponding computational model. We applied this paradigm to a case of congenital heart disease, namely, transposition of the great arteries (TGA) repaired with arterial switch operation. For this purpose, a mock circulatory loop compatible with the CMR environment was constructed and two detailed aortic 3D models (i.e., one TGA case and one normal aortic anatomy) were tested under realistic hemodynamic conditions, acquiring 4D CMR flow. The same 3D domains were used for multi-scale CFD simulations, whereby the remainder of the mock circulatory system was appropriately summarized with a lumped parameter network. Boundary conditions of the simulations mirrored those measured in vitro. Results showed a very good quantitative agreement between experimental and computational models in terms of pressure (overall maximum % error = 4.4% aortic pressure in the control anatomy) and flow distribution data (overall maximum % error = 3.6% at the subclavian artery outlet of the TGA model). Very good qualitative agreement could also be appreciated in terms of streamlines, throughout the cardiac cycle. Additionally, velocity vectors in the ascending aorta revealed less symmetrical flow in the TGA model, which also exhibited higher wall shear stress in the anterior ascending aorta.
Keywords
cardiovascular magnetic resonance imaging
congenital heart disease
mock circulatory loop
rapid prototyping
validation
Authors & Affiliations
9 authors, click to expand affiliations / ORCID
Biglino Giovanni
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
Cosentino Daria
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
Steeden Jennifer A
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
De Nova Lorenzo
Laboratory of Biological Structures Mechanics (LAbS), Politecnico di Milano , Milan , Italy.
Castelli Matteo
Laboratory of Biological Structures Mechanics (LAbS), Politecnico di Milano , Milan , Italy.
Ntsinjana Hopewell
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
Pennati Giancarlo
Laboratory of Biological Structures Mechanics (LAbS), Politecnico di Milano , Milan , Italy.
Taylor Andrew M
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
Schievano Silvia
Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, Great Ormond Street Hospital for Children, NHS Foundation Trust , London , UK.
References (18)
18 references, click to expand
-
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.
J Cardiovasc Magn Reson. 2013 Jan 16;15:2
PMID: 23324211
-
Individualized computer-based surgical planning to address pulmonary arteriovenous malformations in patients with a single ventricle with an interrupted inferior vena cava and azygous continuation.
J Thorac Cardiovasc Surg. 2011 May;141(5):1170-7
PMID: 21334010
-
Hemodynamic study of TCPC using in vivo and in vitro 4D Flow MRI and numerical simulation.
J Biomech. 2015 May 1;48(7):1325-30
PMID: 25841292
-
Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data.
Radiology. 2007 Feb;242(2):490-7
PMID: 17255420
-
Fontan hemodynamics from 100 patient-specific cardiac magnetic resonance studies: a computational fluid dynamics analysis.
J Thorac Cardiovasc Surg. 2014 Oct;148(4):1481-9
PMID: 24507891
-
Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T.
J Cardiovasc Magn Reson. 2011 Oct 04;13:55
PMID: 21970399
-
4D-MR flow analysis in patients after repair for tetralogy of Fallot.
Eur Radiol. 2011 Aug;21(8):1651-7
PMID: 21720942
-
Flow studies on atriopulmonary and cavopulmonary connections of the Fontan operations for congenital heart defects.
J Biomed Eng. 1993 Jul;15(4):303-7
PMID: 7689671
-
Boundary conditions of patient-specific fluid dynamics modelling of cavopulmonary connections: possible adaptation of pulmonary resistances results in a critical issue for a virtual surgical planning.
Interface Focus. 2011 Jun 6;1(3):297-307
PMID: 22670201
-
Predictive modeling of the virtual Hemi-Fontan operation for second stage single ventricle palliation: two patient-specific cases.
J Biomech. 2013 Jan 18;46(2):423-9
PMID: 23174419
-
Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition.
J Cardiovasc Magn Reson. 2012 Apr 27;14:25
PMID: 22541134
-
Computer modeling to tailor therapy for congenital heart disease.
Curr Cardiol Rep. 2013 Sep;15(9):395
PMID: 23881579
-
D-transposition of the great arteries: the current era of the arterial switch operation.
J Am Coll Cardiol. 2014 Aug 5;64(5):498-511
PMID: 25082585
-
Patient specific fluid-structure ventricular modelling for integrated cardiac care.
Med Biol Eng Comput. 2013 Nov;51(11):1261-70
PMID: 23340962
-
4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot.
J Cardiovasc Magn Reson. 2012 Feb 07;14:16
PMID: 22313680
-
Patient-specific modeling of cardiovascular mechanics.
Annu Rev Biomed Eng. 2009;11:109-34
PMID: 19400706
-
A methodological paradigm for patient-specific multi-scale CFD simulations: from clinical measurements to parameter estimates for individual analysis.
Int J Numer Method Biomed Eng. 2014 Dec;30(12):1614-48
PMID: 25345820
-
Image-based modeling of blood flow and vessel wall dynamics: applications, methods and future directions: Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.
Ann Biomed Eng. 2010 Mar;38(3):1188-203
PMID: 20087775