Home LiteratureArticle Details
PMID: 26763174 Published · ppublish English

Structural influence of graft and block polycations on the adsorption of BSA.

Zhang Li, Jin Fengmin, Zhang Tingbin, Zhang Ling, Xing Jinfeng

Abstract

Protein adsorption is considered as an important factor for the low transfection efficiency of polycations in vivo. In this study, two typical polycations of equal molecular weight with different structures were chosen to investigate their adsorption on bovine serum albumin (BSA), including the block copolymer named poly (N-vinylpyrrolidone)-b-poly (2-dimethylaminoethyl methacrylate) (PVP-b-PDMAEMA, i.e. PbP) and graft copolymer named PVP-g-PDMAEMA (PgP), respectively. Fluorescence spectroscopy was used to confirm the binding constants and binding sites between polycations and BSA in static state. The binding constants were 4.1×10(4)M(-1) vs 8.3×10(4)M(-1) and binding sites were 0.3 vs 1.1 for PbP and PgP, respectively, indicating PgP had stronger binding affinity with BSA. Surface plasmon resonance (SPR) was used to study the dynamical non-specific interaction between BSA and polycations as well as the polyplexes. The numbers of both PbP and PgP adsorbed on BSA increased with concentration of polycations increasing, and the number of PgP adsorbed on BSA is higher compared with PbP when their concentration is low. When their concentration is high, the number of PbP adsorbed on BSA is more than that of PgP. However, PgP/DNA polyplexes showed higher adsorption amount compared with PbP/DNA polyplexes at different N/P ratios.

Keywords
Bovine serum albumin Fluorescence spectrum Gene delivery Polycations Surface plasmon resonance
MeSH 主题词
Adsorption DNA/chemistry Kinetics Models, Molecular Molecular Structure Polyamines/chemistry Polyelectrolytes Polymers/chemistry Serum Albumin, Bovine/chemistry Spectrometry, Fluorescence Structure-Activity Relationship Surface Plasmon Resonance
Article Info
Journal
International journal of biological macromolecules
Abbr.
Int J Biol Macromol
Published
2016-11-04
Indexed
2016-02-12
Updated
2016-11-11
Language
English
Country/Region
Netherlands
NLM ID
7909578
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]