主页 文献库文献详情
PMID: 26771764 已发表 · ppublish 英语

Plasma levels of chemokine ligand 20 and chemokine receptor 6 in patients with sepsis: A case control study.

European journal of anaesthesiology ·第 33 卷 ·第 5 期 ·0000-00-00

Klaus Daniel A, Seemann Rudolf, Roth-Walter Franziska, Einwallner Elisa, Motal Michael C, Tudor Bianca, Lebherz-Eichinger Diana, Wiegele Marion, Krenn Claus G, Roth Georg A

摘要

Chemokine ligand 20 (CCL20) is a chemokine released by mainly liver and blood leucocytes. Particularly under pro-inflammatory circumstances it triggers chemotaxis of lymphocytes and dendritic cells via activating receptor chemokine receptor 6 (CCR6) that is specific to it. In experimental sepsis models, the chemokine-receptor pair has been identified as a potential pathophysiological axis affecting mortality.,Measurement of CCL20 and CCR6 plasma levels in septic patients compared with postsurgical, nonseptic patients.,Case control study.,Surgical ICUs of the Department of Anaesthesiology, General Hospital of Vienna, Vienna, Austria.,Plasma levels were measured in 46 patients with sepsis, severe sepsis or septic shock according to current American College of Chest Physicians/Society of Critical Care Medicine criteria at the day of sepsis onset. Plasma levels in 36 postsurgical controls without sepsis admitted to the ICU were investigated. Plasma concentrations were determined by using commercially available ELISA kits. Data are given as median and interquartile range (IQR).,CCL20 and CCR6 plasma levels.,CCL20 plasma levels were significantly increased in the sepsis group: 220.9 pg ml (IQR, 72.8 to 540.1) compared with the ICU controls: 37.0 pg ml (IQR 6.5 to 83.6) (P < 0.0001). Significantly elevated CCR6 levels were found in the sepsis group: 2.47 ng ml (IQR 0.92 to 5.54) compared with the controls: 0.59 ng ml (IQR 0.17 to 1.48) (P < 0.0001). Both CCL20 and CCR6 correlated with the maximum sequential organ failure assessment score (CCL20: P < 0.0001, CCR6: P < 0.0001). Length of ICU admission depended significantly on the logarithm of CCR6 (P = 0.008) and sequential organ failure assessment maximum (P < 0.0001).,There were early increased plasma concentrations of CCL20 and CCR6 in patients with sepsis. CCL20 and CCR6 correlate with severity of illness in ICU patients. Levels of CCR6 predicted the length of patients' admission.

文献信息
期刊
European journal of anaesthesiology
期刊简称
Eur J Anaesthesiol
发表日期
0000-00-00
收录日期
2016-04-06
更新日期
2016-04-06
语言
英语
国家/地区
England
NLM ID
8411711
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]