Home LiteratureArticle Details
PMID: 26793288 Published · epublish English Journal Article

Velocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics.

Sarrami-Foroushani A, Nasr Esfahany M, Nasiraei Moghaddam A, Saligheh Rad H, Firouznia K, Shakiba M, Ghanaati H, Wilkinson ID, Frangi AF

Abstract

Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results.

Keywords
Carotid Bifurcation Fluid Dynamics Time-Resolved Three-Dimensional Phase-Contrast Magnetic Resonance Imaging (TR 3D PC MRI)
作者与单位
共 9 位作者,点击展开单位 / ORCID
Sarrami-Foroushani Ali
Department of Chemical Engineering, Isfahan University of Technology, Isfahan, Iran.
Nasr Esfahany Mohsen
Department of Chemical Engineering, Isfahan University of Technology, Isfahan, Iran.
Nasiraei Moghaddam Abbas
Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
Saligheh Rad Hamidreza
Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran.
Firouznia Kavous
Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran.
Shakiba Madjid
Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran.
Ghanaati Hossein
Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran.
Wilkinson Iain David
Academic Unit of Radiology, University of Sheffield, Sheffield, South Yorkshire, United Kingdom.
Frangi Alejandro Federico
Department of Mechanical Engineering, The University of Sheffield, Sheffield, United Kingdom.
Article Info
Journal
Iranian journal of radiology : a quarterly journal published by the Iranian Radiological Society
Abbr.
Iran J Radiol
ISSN
1735-1065
Published
2015-10-00
电子出版
2015-00-17
页码
e18286
Language
English
Country/Region
Iran
NLM ID
101233229
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]