主页 文献库文献详情
PMID: 26863157 已发表 · ppublish 英语

Enhanced X-ray absorption for micro-CT analysis of low density polymers.

Journal of biomaterials science. Polymer edition ·第 27 卷 ·第 9 期 ·0000-00-00

Crica Livia Elena, Wengenroth Jonas, Tiainen Hanna, Ionita Mariana, Haugen Håvard Jostein

摘要

X-ray microtomography (micro-CT), one of the most resourceful instruments for high resolution 3D analysis, can provide qualitative and quantitative accurate structural and compositional information for a broad range of materials. Yet its contribution to the field of biopolymeric materials science is often limited by low imaging contrast due to scarce X-ray attenuation features, particularly for sponges and foam-like structures. This limitation can be overcome to some extent by adjusting the working parameters of micro-CT equipment. However, such approach also facilitates noise and artefacts, and solving the signal-to-noise trade-off has been always problematic. Searching for alternatives turns one's attention towards the improvement of X-ray attenuation features. While several studies report the use of contrast agents for biological materials, studies to integrate multiple micro-CT approaches for biopolymers were not conducted so far. This method paper is thus aimed to serve as a platform for micro-CT analysis of low X-ray absorptive polymers. Here, several contrast enhancing artifices were developed and trialled on gelatin and poly(vinyl alcohol) biopolymer composites (GP). Accordingly, GP were modified with iodine, barium, silver-based chemicals and hexa(methyl disilazane) by two different methods, i.e. addition of high atomic number chemicals during materials synthesis and post-synthesis staining, respectively. Consequently, cross-sectional scanning electron microscopy emerged as complementary characterization, aimed to confirm the reproducibility of samples morphological features. The most versatile methods were barium chloride additive incorporation and iodine staining coupled with hexa(methyl disilazane) chemical drying. Both methods significantly improved the X-ray absorbance of our polymeric samples, providing better contrast of micro-CT tomograms.

关键词
Micro-CT X-ray absorption contrast enhancement low density polymers
文献信息
期刊
Journal of biomaterials science. Polymer edition
期刊简称
J Biomater Sci Polym Ed
发表日期
0000-00-00
收录日期
2016-04-27
更新日期
2016-04-27
语言
英语
国家/地区
England
NLM ID
9007393
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: [email protected]