Stereoradiography imaging motion artifact: does it affect radiographic measures after spinal instrumentation?

Simon Anne-Laure, Ferrero Emmanuelle, Noelle Larson A, Kaufman Kenton R

Abstract

Stereoradiography imaging (SRI) is an accurate and reliable low-dose radiographic method. However, patients must remain motionless during image acquisition. Motion artifacts are frequently noted. The aims of the study were to determine the incidence of the SRI motion artifact and assess if motion during SRI acquisition affects radiographic measurements.,In this retrospective study, 198 patients with spinal instrumentation had biplanar SRI radiographs performed, of whom 39 had concomitant conventional radiographs. Eight coronal and sagittal spinal parameters were independently measured on SRI and conventional radiographs for the 39 patients by 2 observers. Inclusion criteria were: presence of spinal instrumentation of more than six levels and an SRI motion artifact identified on the coronal and/or the sagittal views on either the spinal rods or on the limbs. Means were compared between both types of radiographs using the Student's t test; intraclass correlation coefficients (ICCs) were used for intraobserver reproducibility and interrater reliability.,A motion artifact was identified in 19.7 % (n = 39, mean age 19.5 ± 1.7 years) of the cases. There were no differences in any of the coronal or sagittal plane measurements between SRI and X-rays. Intraobserver reliability and interrater reproducibility was high (range 0.81-0.98).,Motion artifact during full-spine stereoradiography imaging acquisition is frequent, but does not affect spinal measurements. SRI with a motion artifact can be used to produce reliable measurements of the sagittal and coronal parameters. Some SRI images with a motion artifact may suggest loss of fixation or bending of the rods. However, after becoming familiar with the appearance of the motion artifact, repeat radiographs are rarely indicated.,14-004872.,Level IV.

Keywords
EOS® Low-dose imaging Movement artifact Radiographic measures Spinal surgery Stereoradiography
Article Info
Journal
European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
Abbr.
Eur Spine J
Published
0000-00-00
Indexed
2016-03-04
Updated
2016-03-05
Language
English
Country/Region
Germany
NLM ID
9301980
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]