Home LiteratureArticle Details
PMID: 27239651 Published · ppublish English

A novel approach to assess pulmonary function in patients with chronic obstructive pulmonary disease using tissue velocity imaging.

Medical ultrasonography ·Vol. 18 ·No. 2 ·0000-00-00

Zheng Xiao-Zhi, Wu Jing, Tan Xu-Yan

Abstract

To explore the feasibility of quantitative evaluation of pulmonary function in patients with chronic obstructive pulmonary disease (COPD) using tissue velocity imaging (TVI) and strain rate imaging (SRI) via transthoracic lung ultrasonography.,Eighty inpatients with clinically diagnosed COPD underwent pulmonary function test and transthoracic lung ultrasound on the same day. Lung ultrasound variables and pulmonary function parameters were analyzed.,All patients with COPD had faster breathing and significant reduced lung function compared with healthy participants (p<0.05). The lung ultrasound parameters, velocity (max-min, cm/s), displacement (max-min, mm), strain (max-min, %) and strain rate (max-min, 1/s) were significantly higher in patients with COPD (p<0.05). A good negative correlation was found between lung ultrasound variables and pulmonary function parameters in patients with COPD. Stepwise multiple regression analysis indicated that the velocity (max-min, cm/s) was the only independent determinant of FEV1/FVC (%). With the use of FEV1/FVC<70% as the criteria of irreversible pulmonary function impairment to distinguish an abnormal pulmonary function, the area under the ROC was 0.99 for the velocity (max-min, cm/s) of the lung tissue in the process of breathing. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the cut off value (1.19 cm/s) was 97.63%, 100%, 100%, 80%, and 98%, respectively (p<0.001).,Tissue velocity imaging via transthoracic lung ultrasound is a useful modality in the assessment of pulmonary function in patients with COPD.

Article Info
Journal
Medical ultrasonography
Abbr.
Med Ultrason
Published
0000-00-00
Indexed
2016-05-30
Updated
2016-05-30
Language
English
Country/Region
Romania
NLM ID
101522985
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: [email protected]